(C502CS8) Quartz High-Capacity Cuvette, 50 mm Path, 125 mL
Original price was: $179.00.$162.00Current price is: $162.00.
C502CS8 is a JGS1 quartz high-capacity cuvette with a 50 mm optical path, a Two-Way Light transmission layout and 125 mL nominal capacity for UV/Vis work. Its open-top square chamber gives direct access for filling, rinsing and visual checks, and this option includes a lid. Sold as 1 cuvette per listed price unit.
Description
C502CS8 is a large-format JGS1 quartz cuvette for UV/Vis methods that use a 50 mm optical path and a broad static sample chamber. Its 125 mL nominal capacity and 50 × 50 × 53 mm internal space make it easier to fill, inspect and rinse from above than a narrow cell. This option includes a lid, while the optical layout remains a straightforward Two-Way Light transmission path through opposite sides.
- Path Length
- 50 mm
- Sample Volume (Nominal)
- 125 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | High-Capacity Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 50 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 125 mL |
| External Dimensions | 54 × 54 × 55 mm |
| Cell Body Dimensions | 54 × 54 × 55 mm |
| External Dimensions Scope | Body Only |
| Internal Dimensions | 50 × 50 × 53 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C502CS8 when your method needs a 50 mm transmission path together with a large open sample region. The square open-top body is useful when you want direct top access for loading bulk liquid, checking the liquid condition visually, or rinsing the chamber between runs. The included lid covers the opening during routine handling, but the cell is still selected and used as an open-top cuvette rather than a sealed pressure assembly.
What makes this option different
- 50 mm optical path for methods written around a longer transmission distance.
- 125 mL nominal capacity with a large 50 × 50 × 53 mm internal chamber for bulk liquid samples.
- Two-Way Light layout for transmission through one opposing pair of optical faces.
- Open-top access for direct filling, inspection and rinsing from above.
- Included lid to cover the chamber during preparation and routine handling.
- Fused integrated construction as the supplier’s construction term for this cell body, supporting a fixed large-format cuvette design rather than a demountable plate-style sample assembly.
Using this cell
Fill the cell from the top and keep the liquid level high enough for the beam path used by your instrument. Remove visible bubbles from the transmission path before measurement, and keep the same orientation for blank and sample if your procedure depends on consistent positioning.
The broad square chamber is suited to static liquid loading rather than tubing connections or flow use. The lid is for covering the opening during handling and setup; it should not be treated as a leak-tight, pressure-rated or transport-sealed closure.
First-use check
Inspect the optical faces and chamber for residue, dust or handling marks before first use. Rinse with a cleaning liquid suitable for your process, test the empty cell in the holder for stable seating, and run your blank in the same orientation planned for the sample.
Fit and optical alignment
The body dimensions are 54 × 54 × 55 mm, and these figures apply to the body only rather than a lid-inclusive overall size. Check that your holder can accept the square body and that the beam is aligned through the intended pair of opposite optical faces used for Two-Way Light transmission.
Z Height is not stated for this item. If your instrument has a fixed beam-center height or tight clearance above the cell, check those points before ordering instead of assuming fit from the 50 mm path length alone.
Solvents and cleaning
This cuvette is made from quartz for UV/Vis use, but the chemical limits of this exact assembly are not established here. If your sample, rinse solvent or cleaning method involves aggressive chemicals, elevated temperature or long contact time, check suitability for the complete cell before ordering.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue. For general background on cuvette construction, see the MQ cuvette fabrication glossary.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions related to dimensions, optical path length, sample volume, optical windows, Z Height, closures or tolerance requirements. Send a dimensioned drawing or labelled sketch, together with holder details and sample conditions, through the contact page and quote C502CS8.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.