(C102CR18) Quartz Micro Cuvette, 10 mm Path, 1.75 mL
Original price was: $72.00.$65.00Current price is: $65.00.
C102CR18 is a quartz micro cuvette for UV/Vis spectroscopy with a 10 mm optical path and 1.75 mL nominal capacity. This Two-Way Light version uses an open-top body with a 5 mm sample-region channel, giving you direct filling access and a broader sample region than narrower slit variants in the same family. Supplied as 1 cuvette per price unit; a lid is included.
Description
C102CR18 is a quartz micro cuvette for UV/Vis work with a 10 mm optical path, a 1.75 mL nominal capacity and a Two-Way Light layout. Its open-top body and 5 mm sample-region channel make it a practical choice when you want direct access for filling and visual checking, while keeping the larger-capacity option within this compact micro cuvette format.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.75 mL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top (Cell Body) |
| Detection Channel Width | 5 mm |
Choose this option
Choose C102CR18 when your method uses a 10 mm path and you prefer a micro cuvette with more nominal fill capacity than the smaller-volume options in this body family. The 5 mm sample-region channel can also be helpful when your filling routine and beam coverage are easier to manage with a broader illuminated region rather than a very narrow slit.
What makes this option different
- 10 mm optical path for UV/Vis measurements that use a standard transmission path length.
- 1.75 mL nominal capacity for users who want the larger-capacity option within this compact cell format.
- 5 mm sample-region channel for methods that suit a broader illuminated sample region than narrower slit versions.
- Open-top body for direct filling, rinsing and visual sample checking before measurement.
- Two-Way Light layout for transmission measurements through the defined optical faces.
- Quartz cell body selected for UV/Vis use across the stated 200–2500 nm range.
Using this cell
Fill the cell from the top and make sure the sample cleanly covers the illuminated region before measurement. The open access makes it easier to rinse, load and inspect the sample, but the nominal 1.75 mL capacity is not a minimum working volume, so your actual fill level still needs to suit your beam position and method.
Use the same orientation for blank and sample measurements, and check that the light path is free from bubbles or dry areas. If you use a lid during handling or measurement, treat it as a cover rather than a pressure or leak-tight closure.
First-use check
Inspect the optical faces and interior on arrival and before first use. After rinsing, place the filled cell in your holder and confirm stable seating, full beam coverage and a clear, bubble-free transmission path.
Fit and optical alignment
The uncapped body dimensions are 12.5 × 12.5 × 45 mm. These dimensions describe the bare cell body, so leave additional clearance for the lid and for top access during filling, emptying and cleaning.
Z Height is not specified for this SKU. If your instrument has a fixed beam center or limited vertical adjustment, check beam position and holder seating before ordering.
Solvents and cleaning
This option uses a powder-fused construction in the supplier’s wording, but the exact chemical limits for this SKU are not stated here. Choose cleaning and sample contact conditions with the full wetted assembly in mind, especially if your method uses aggressive reagents or a demanding cleaning routine.
For general fabrication background, see this fabrication guide. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
Supplied as 1 quartz micro cuvette per price unit. A lid is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz projects for changes to dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication requirements. Send a drawing or labelled sketch, plus your holder or instrument details, critical dimensions, sample conditions and target quantity. Discuss your requirements and reference part number C102CR18.
Additional information
| Weight | 30 g |
|---|