(C104CS98) Quartz Ultra-Micro Cuvette, 10 mm Path, 100 µL
Original price was: $175.00.$158.00Current price is: $158.00.
C104CS98 is a JGS1 quartz ultra-micro cuvette with a 10 mm optical path, 100 µL nominal capacity and Four-Way Light geometry for fluorescence spectroscopy. Its open-top body gives direct access for filling and visual inspection before measurement. Sold as 1 cuvette.
Description
C104CS98 is a JGS1 quartz ultra-micro cuvette with a 10 mm optical path and 100 µL nominal capacity for fluorescence spectroscopy. The Four-Way Light design and open-top body make it a practical choice when you need side optical access around a compact sample region and want to load the sample directly from above.
This option suits laboratory work built around a small-volume cell rather than a closed cuvette format. The open top helps with pipette loading and visual checking before the run, while the 100 µL nominal capacity gives a clear target size for routine small-volume preparation.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 100 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 100 µL |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C104CS98 when you need a 10 mm path in an ultra-micro format and want direct top access for loading the sample. The 100 µL nominal capacity and Four-Way Light layout make it suitable for fluorescence setups that depend on a compact sample chamber with optical access from multiple sides.
What makes this option different
- 10 mm optical path in an ultra-micro cuvette format.
- 100 µL nominal capacity for small-volume sample handling.
- Four-Way Light geometry for optical access from four sides around the sample region.
- Open-top cell body for direct filling and inspection before measurement.
- JGS1 quartz material for fluorescence spectroscopy use.
Using this cell
Fill the cell carefully from the open top and make sure the illuminated region is covered during measurement. Avoid bubbles, droplets and dried residue on the optical faces, and keep the same seating direction for both blank and sample so the optical arrangement stays consistent.
Because this is an open-top body, handle it as a bench-loaded cell rather than a sealed assembly. The stated 100 µL is the nominal capacity for this option and should not be treated as a guaranteed minimum working volume.
First-use check
Before your first measurement, inspect the cell for clean optical faces and confirm that it sits securely in the holder without tilt. Run a blank in the same orientation you will use for the sample, and confirm that the filled sample covers the beam path without trapped air.
Fit and optical alignment
Check your holder and sample compartment before ordering. This ultra-micro geometry must fit the available clearance, and the instrument beam must pass through the intended sample region rather than a position assumed from path length or nominal volume alone.
No released Z Height value is provided for this option. If your instrument has a fixed beam height or a tight holder geometry, send the holder model or a drawing with the available clearance so the fit can be reviewed before purchase.
Solvents and cleaning
Quartz is widely used in optical cells, but the exact chemical limits for this assembled cuvette are not established here. If your method involves aggressive solvents, long contact times or heated cleaning, check the full sample and cleaning conditions before use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean optical faces gently with suitable non-abrasive laboratory or optical wipes. For general fabrication background, see MQ Cuvette Fabrication Glossary.
Included with this option
Supplied as 1 cuvette per sale. No closure or additional accessory is specified for this option.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch together with your holder or instrument details, the critical dimensions, sample conditions and target timing. You can contact us about a custom cuvette project and reference C104CS98.