(C104CS99) Quartz Ultra-Micro Cuvette, 10 mm Path, 200 µL
Original price was: $156.00.$141.00Current price is: $141.00.
C104CS99 is a JGS1 quartz ultra-micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light access and 200 µL nominal capacity. Its open-top cell body allows direct filling and visual inspection before measurement. Sold as 1 cuvette per listed unit.
Description
C104CS99 is a JGS1 quartz ultra-micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light geometry and 200 µL nominal capacity. This combination is useful when you need a defined 10 mm path in a small-volume cell and want optical access from multiple sides around the sample region.
The open-top body lets you fill the cell directly and check the liquid condition before measurement. That is especially helpful with small sample volumes, where bubbles, uneven fill or droplets on the optical faces can affect the illuminated area.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 200 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 200 µL |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C104CS99 when your method needs a 10 mm path in an ultra-micro quartz cell and your fluorescence setup uses side optical access around a compact sample chamber. The 200 µL nominal capacity gives you a small-volume format without moving to a flow cell or a demountable assembly, while the open top keeps filling simple.
What makes this option different
- 10 mm optical path for methods that require this path length in a compact cell format.
- Four-Way Light configuration for fluorescence arrangements that use optical access from more than one side.
- 200 µL nominal capacity for a small sample chamber while retaining a complete cuvette body.
- Open-top cell body for direct pipette loading and visual checking before measurement.
Using this cell
Fill from the top and make sure the sample covers the illuminated region used by your instrument. The 200 µL figure is the nominal chamber capacity; it is not a minimum working volume.
Use the same seating orientation for blank and sample measurements, and check for bubbles before reading. Wipe away droplets and fingerprints from the outside optical faces so the measurement area stays clear.
First-use check
- Inspect the optical faces and top opening for residue or handling marks.
- Rinse with a suitable liquid for your method before first measurement.
- After filling, confirm that the sample region is covered and free from visible bubbles.
Fit and optical alignment
Review holder opening, sample-compartment clearance and beam position before ordering, especially for fluorescence setups. Four-Way Light describes the optical access category, but it does not by itself establish compatibility with every fluorimeter or holder geometry.
This product is identified as an ultra-micro cuvette, but external body dimensions and Z Height are not stated here. If your setup depends on a defined beam height or limited holder clearance, send the holder model or a drawing with the available space and beam location for review.
Solvents and cleaning
Quartz is widely used for optical cells, but the chemical limits for this exact assembly are not specified here. If your samples or cleaning routine involve organic solvents, aggressive reagents, elevated temperature or long contact time, check suitability for the exact cell assembly before routine use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Wipe the exterior optical faces gently with non-abrasive optical tissue. For fabrication background, see MQ Cuvette Fabrication Glossary.
Included with this option
Sold as 1 cuvette per listed unit. This is an open-top cell body. Additional supplied accessories are not listed here.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a related quartz cell with different dimensions, optical path length, sample volume, optical windows, Z Height, closure details or other fit requirements, we can review a custom enquiry. Send your drawing or holder details and your application requirements through Discuss your requirements, and include part number C104CS99 as a reference.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.