(C104CD15) Quartz Ultra-Micro Cuvette, 10 mm Path, 50 µL
Original price was: $223.00.$201.00Current price is: $201.00.
C104CD15 is a JGS1 quartz ultra-micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light access and 50 µL nominal capacity. Its open-top body allows direct filling and visual checking of the sample chamber. Supplied as 1 cuvette per price unit.
Description
C104CD15 is an ultra-micro JGS1 quartz cuvette for fluorescence spectroscopy when you need a 10 mm optical path with a 50 µL nominal capacity. The open-top body gives you direct access for loading and inspection, and the Four-Way Light configuration supports optical access around the sample region. Supplied as 1 cuvette per price unit, it is a practical choice when a small-volume cell is needed without moving to a larger body style.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 50 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 50 µL |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C104CD15 when your method uses a 10 mm path but a 50 µL nominal volume gives you a more comfortable fill range than smaller ultra-micro options. The open top suits direct pipette loading, and the Four-Way Light layout is intended for fluorescence setups that use side optical access around the sample region.
What makes this option different
- 10 mm optical path in an ultra-micro cuvette format.
- 50 µL nominal capacity for small-volume fluorescence measurements.
- Four-Way Light configuration for optical access from multiple sides of the sample region.
- Open-top body for direct filling, inspection and rinsing.
- JGS1 quartz cell body for fluorescence spectroscopy use.
Using this cell
Fill the cell from the top and confirm that the illuminated region is fully covered during measurement. In small-volume handling, it helps to check for bubbles and droplets on the optical faces before placing the cell in the holder.
Use a consistent seating direction for blank and sample runs so the same faces present to the optical path each time. The stated 50 µL is the nominal cell capacity for this option; it should not be treated as a released minimum working volume.
First-use check
Inspect the optical faces for dust or residue before first use, then rinse with a suitable liquid for your method. Test the cell in the holder before loading a critical sample, and verify with a blank that the beam passes through liquid without trapped air.
Fit and optical alignment
Check the holder opening, compartment clearance and beam position before ordering, especially in fluorescence accessories with defined beam geometry. Four-Way Light indicates the supported optical access category, but it does not by itself establish fit with every instrument or holder.
A released Z Height value is not established for this SKU, so holder compatibility should be checked against your actual setup rather than assumed from appearance or family name alone. If you need a fit review, send your holder model or drawing to https://machinedquartz.com/contact/.
Solvents and cleaning
The body is JGS1 quartz, but the exact chemical limits for this selected assembly are not established here. If your method involves aggressive solvents, mixed cleaning routines or extended contact time, check suitability for the complete assembly before routine use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. For routine care, rinse promptly after use and wipe the exterior optical faces gently with non-abrasive optical tissue. For general fabrication background, see https://machinedquartz.com/fabrication-method-of-cuvettes/.
Included with this option
1 ultra-micro cuvette. No additional closure or accessory is specified for this option.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; the final quantity, feasibility, specifications, price and production time are confirmed in the project quotation. Modified designs are quoted separately from the listed SKU. Please reference C104CD15 when you contact us at https://machinedquartz.com/contact/.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.