(C104TS19) Quartz Screw-Top Cuvette, 10 mm Path, 4.5 mL
Original price was: $346.00.$312.00Current price is: $312.00.
C104TS19 is a JGS1 quartz screw-top cuvette with a 10 mm optical path, 4.5 mL nominal capacity and Four-Way Light access. Its single long neck with injectable screw cap gives top access above a compact 12.5 × 12.5 mm base. Supplied as 1 cuvette per listed price unit; closure included.
Description
C104TS19 is a JGS1 quartz screw-top cuvette designed around a 10 mm optical path with optical access on four sides of the sample region. This version combines a 4.5 mL nominal capacity with a single long-neck opening and an included injectable screw cap, giving you top access while keeping the base in a compact 12.5 × 12.5 mm square format.
The long-neck geometry is the main reason to choose this model. It places the sample entry above the optical body, which can make filling or introducing liquid from above more convenient when you want to keep hands and tools away from the optical faces during handling.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 4.5 mL
- Opening Configuration
- Single Long Neck with Injectable Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 4.5 mL |
| Body Height | 45 mm |
| Overall Height with Closure | 114 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Included | Yes |
| Port Count | 1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Single Long Neck with Injectable Screw Cap |
Choose this option
Choose C104TS19 when your method uses a 10 mm path and you want a long-neck screw-top cuvette rather than a short-neck or open-top format. The Four-Way Light layout supports optical access around the sample region, while the 4.5 mL nominal capacity and included closure make it suitable for covered liquid handling in compatible fluorescence or transmission setups.
What makes this option different
- 10 mm optical path with Four-Way Light access around the sample region.
- 4.5 mL nominal capacity in a compact square-base cell body.
- Single long neck for top access above the optical body.
- Injectable screw cap included for covered filling and handling.
Using this cell
Fill or introduce the sample through the top opening and make sure the liquid covers the beam area used by your instrument. For repeatable measurements, keep the same cell orientation for blank and sample, and keep bubbles, droplets and residue away from the optical faces.
The included closure covers the opening during handling and measurement steps. It should not be treated as a pressure-rated or leak-tested seal for pressurised, transport or closed-circuit use.
First-use check
- Inspect the optical faces, neck and cap for chips, particles or residue.
- Place the cell in your holder and confirm that the long neck clears the compartment above.
- Rinse with a suitable liquid for your method and run a blank before analytical use.
Fit and optical alignment
The base measures 12.5 × 12.5 mm and the optical body height is 45 mm. The overall height with cap is 114 mm, so the narrow base does not mean the cell is short; the long neck and cap need substantial clearance above the holder.
Z Height is not listed for this item, and a full external size envelope is not established here beyond the confirmed base and capped height. If your instrument has a fixed beam position or limited compartment height, check both beam alignment and headroom before ordering.
Solvents and cleaning
This cuvette uses Molded 83 fabrication. Choose your sample and cleaning routine for the complete assembled item, including the closure, especially if your method involves aggressive chemicals, elevated temperature or extended contact time.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Discuss your requirements and quote part number C104TS19.
Design notes for this configuration: Long-Neck Fluorescence Cuvette: Sampling Above the Optical Body
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.