Quartz Sample Chamber Cuvette (C0.51WS) – 0.5mm Slot Depth Reflection Cell

Weight30 g
SKU: C0.51WS

Original price was: $181.00.Current price is: $163.00.

In Stock

Quartz slot depth 0.5 mm quartz sample chamber cuvette for reflection, Standard 80 (>80% transmittance). Two-Way Light. 190–2500 nm. SKU: C0.51WS.

In Stock
Add to Wishlist
Add to Wishlist
SKU: C0.51WS Categories: , , Brand:
Worldwide Timed Dispatch Available
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Standard cuvettes ship in 3-5 days. Custom items 1-2 weeks.

Description

The C0.51WS is a quartz quartz sample chamber cuvette for reflection with slot depth 0.5 mm path length and two-way light optical configuration — two opposite vertical faces are polished to optical grade, forming the standard transmission geometry for UV-Vis absorbance measurements. Fabricated using Standard 80 (>80% transmittance) — precision-glued quartz construction, an industry-proven assembly method. Showcases an ultra-flat square plate design (50mm x 50mm x 2mm) with a precision-machined 0.5mm slot depth, creating a thin-layer sample chamber ideal for reflection spectroscopy. The flat, wafer-like profile allows direct mounting in reflection measurement setups.

Technical Specifications — Quartz Sample Chamber Cuvette For Reflection
MaterialQuartzSKUC0.51WS
Path Lengthslot depth 0.5 mmInternal Volume
Optical Windows2 (Two-Way Light)FabricationStandard 80
Transmittance>80%Wavelength190–2500 nm
Exterior Dimensions50 × 2 × 50 mmInterior Dimensions40 × 0.5 × 40 mm
ClosureNone (Open Top)Package1pc/ea

Spectroscopy Applications

UV-Vis Absorbance Spectroscopy — quantitative concentration, kinetics, Beer–Lambert studies
DNA / RNA Quantification — nucleic-acid purity checks at 260/280 nm
Protein Assays — Bradford, BCA, Lowry, and direct A280 measurements
Enzyme Kinetics — real-time substrate conversion and inhibition studies
Water Quality & Environmental — COD, nitrate, phosphate, heavy-metal colorimetric tests
Pharmaceutical QC — dissolution testing, drug concentration, stability monitoring
Chemical Reaction Monitoring — reaction progress tracking via absorbance changes
Teaching & Student Labs — durable quartz cells for undergraduate spectroscopy courses

Why Two-Way Light?

Two-way light cuvettes have two opposite vertical faces polished to optical grade, forming the standard transmission geometry for UV-Vis absorbance measurements. The remaining two faces are frosted to minimize stray-light interference, providing clean baseline performance for quantitative spectrophotometry.

Why Standard 80?

Standard 80 uses precision-glued quartz construction — an industry-proven assembly method delivering >80% UV transmittance from 200–2500 nm. The optical adhesive bond is optimized for aqueous (water-based) solutions, making this fabrication ideal for routine spectrophotometry, QC testing, and educational labs where the sample matrix is known and gentle. Standard 80 offers a cost-effective entry point with reliable, repeatable results under normal operating conditions.

Usage Tips

  • Rinse with a compatible solvent (e.g., ethanol or the measurement solvent) before first use to remove any residual particles.
  • Do not use abrasive materials or brushes on the polished optical faces — wipe gently with lens tissue.
  • Suitable for aqueous (water-based) solutions only. Do not use with organic solvents, strong acids, or strong bases.
  • Store in the original protective case to prevent scratches on the optical windows.
  • For baseline correction, fill with your reference solvent, cap the cuvette, and run a blank before sample measurements.
Custom Orders
Need a non-standard path length, volume, window configuration, or closure type? We manufacture quartz cuvettes to your exact specifications. Request a custom quote.
Disclaimer: Specifications are nominal values measured under standard laboratory conditions. Actual transmittance may vary slightly with wavelength and sample conditions. Images are representative; minor cosmetic variations between production batches are normal and do not affect optical performance.

Additional information

Weight30 g

Reviews

There are no reviews yet.

Be the first to review “Quartz Sample Chamber Cuvette (C0.51WS) – 0.5mm Slot Depth Reflection Cell”

You may also like…

10%
Quartz 2mm/0.5mm Custom Quartz Sample Flow Cell, Standard 80, Two-way Light, 1pc/ea, C0.52WS

Quartz 2mm/0.5mm Custom Quartz Sample Flow Cell, Standard 80, Two-way Light, 1pc/ea, C0.52WS

30 g
In Stock
Original price was: $188.00.Current price is: $170.00.
Add to Wishlist
Add to Wishlist
10%
Quartz 2mm Micro Volume Cuvette, 500ul, Standard 80, Two-way Light, No Cap, 1pc/ea, C022WS

Quartz 2mm Micro Volume Cuvette, 500ul, Standard 80, Two-way Light, No Cap, 1pc/ea, C022WS

30 g
In Stock
Original price was: $80.00.Current price is: $72.00.
Add to Wishlist
Add to Wishlist
10%
Quartz slot depth 0.5 mm Quartz Sample Chamber Cuvette For Reflection, Standard 80, Two-way Light, 1pc/ea, C011WS1
Add to Wishlist
Add to Wishlist
10%
Quartz 2mm Ultra-Micro Cuvette, 20ul, Standard 80, Two-way Light, No Cap, 1pc/ea, C022WS2

Quartz 2mm Ultra-Micro Cuvette, 20ul, Standard 80, Two-way Light, No Cap, 1pc/ea, C022WS2

30 g
In Stock
Original price was: $204.00.Current price is: $184.00.
Add to Wishlist
Add to Wishlist
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare