(C102CS42) Glass Micro Cuvette, 10 mm Path, 350 µL, Pack of 2
Original price was: $34.00.$31.00Current price is: $31.00.
C102CS42 is a glass Micro Cuvette for visible absorbance measurements, combining a 10 mm optical path with a 350 µL nominal volume and a 1 mm sample-region width in a Two-Way Light layout. This option suits methods that need a full 10 mm path in a compact micro-volume format. Sold as a pack of 2; the package includes closures.
Description
C102CS42 is a glass Micro Cuvette for visible absorbance work with a 10 mm optical path in a compact body. It combines a 350 µL nominal volume with a 1 mm sample-region width and a Two-Way Light layout, making it useful when your method needs a standard path length without moving to a larger cuvette format. This MQ sale unit is offered as a pack of 2, and the package includes closures.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Visible Absorbance Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 1 mm |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Glass |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Detection Channel Width | 1 mm |
Choose this option
Choose C102CS42 when your method calls for a 10 mm absorbance path but your sample volume and cell footprint need to stay small. The 1 mm sample-region width is part of this specific geometry, so it is worth selecting when that narrow sample region matters to your filling approach or measurement setup. The supplied closure helps cover the opening during routine handling, while the glass body is intended for visible-range use at 350–2000 nm.
What makes this option different
- 10 mm optical path in a micro-format cell for methods that use this common absorbance path length.
- 350 µL nominal volume for small-volume work without switching to a full-size cuvette body.
- 1 mm sample-region width as part of this option’s stated sample geometry.
- Two-Way Light layout for transmission measurements through the defined optical path.
- MQ sale unit of 2 for the listed priced option; closures are included.
Using this cell
Fill the cell so the illuminated path is covered during measurement, and load the sample carefully to avoid bubbles sitting in the optical region. For blank and sample readings, keep the same orientation each time so the optical faces and sample position remain consistent.
The 350 µL figure is a nominal capacity, not a minimum working volume. In practice, the fill level you need depends on your instrument beam position and how fully the liquid covers the light path in your own setup.
First-use check
- Inspect the optical faces and edges for chips, dust or residue.
- Test the uncapped body in your holder before routine use.
- Add liquid and verify that your normal fill level covers the beam area.
- Run blank and sample with the same cell orientation.
Fit and optical alignment
The uncapped cell body is 12.5 × 12.5 × 45 mm. That square-body size can help when you are matching the cuvette to a holder designed around compact rectangular cells, but it is still important to check holder width, insertion depth and the space above the opening.
Z Height is not specified for this item. If your instrument requires a known beam-center height, confirm that point before ordering. The stated dimensions apply to the uncapped body only, so allow extra vertical clearance for the supplied closure in your installation.
Solvents and cleaning
This cuvette uses Standard 80 construction. For this assembled cell, exact chemical compatibility is not specified, so check both the sample liquid and cleaning liquid against the complete wetted assembly before using unfamiliar reagents.
Use non-abrasive cleaning methods on the optical faces. Rinse promptly after use, and avoid harsh cleaning choices that may not suit the assembled glass-and-closure combination. The product is intended for visible absorbance use rather than UV work.
Included with this option
Supplied as 2 micro cuvettes. Lids are included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom quartz versions for requirements involving dimensions, path length, sample volume, optical windows, Z Height, closures and fabrication. Send a labelled drawing or sketch together with holder details, critical dimensions, sample conditions and target quantity. Discuss your requirements and quote part number C102CS42.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.