(C302CE8) Glass Standard Cuvette, 30 mm Path, 10.5 mL
Original price was: $38.00.$35.00Current price is: $35.00.
C302CE8 is a glass standard cuvette for visible absorbance work with a 30 mm optical path, Two-Way Light layout and 10.5 mL nominal capacity. Its open-top body suits direct filling, and a closure is included. Sold as a pack of 4 cuvettes.
Description
C302CE8 is a glass standard cuvette for visible absorbance measurements that use a 30 mm optical path. The longer path, open-top body and 10.5 mL nominal capacity make it a practical choice when your method needs a deeper liquid column in a familiar rectangular cell format. This listing is sold as a pack of 4 cuvettes, with a closure included.
- Path Length
- 30 mm
- Sample Volume (Nominal)
- 10.5 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | Visible Absorbance Spectroscopy |
| Path Length | 30 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 10.5 mL |
| External Dimensions | 32.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 32.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Glass |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C302CE8 when your method is written for a 30 mm cell and visible-range use is appropriate. The open top makes filling and rinsing straightforward, while the included closure can cover the opening during normal handling between preparation and measurement steps.
What makes this option different
- 30 mm optical path for methods that require a longer path than a standard 10 mm cell.
- Two-Way Light layout for straight-through absorbance measurements.
- 10.5 mL nominal capacity in a rectangular standard-cuvette format suited to bench filling and transfer.
- Pack of 4 cuvettes per listed MQ price unit, with a closure included.
Using this cell
Fill the cell from the top and make sure the liquid level covers the instrument beam during measurement. For routine blank and sample work, keep the same orientation in the holder and remove visible bubbles before taking a reading.
The closure can cover the top during ordinary bench handling, but this page does not set a pressure, leak-tightness or defined evaporation-control rating. If your procedure depends on those conditions, check the full closure requirements before ordering.
First-use check
- Inspect each cuvette for shipping damage, dust or fingerprints on the optical faces.
- Test-fit one empty cell in your holder before preparing a full run.
- Fill with blank solution and confirm that the beam passes through the intended sample region without clipping.
- Confirm that your method falls within the stated 350–2000 nm range.
Fit and optical alignment
The stated 32.5 × 12.5 × 45 mm dimensions apply to the uncapped cell. Use that uncapped body size to check holder seating and physical clearance in your instrument.
Z Height is not established for this SKU. If your instrument uses a fixed beam-center height, confirm that fit directly rather than relying on outer body shape alone.
Solvents and cleaning
This glass cell is specified for visible absorbance use, but the chemical limits for this exact assembly are not established here. Do not assume compatibility with a particular acid, alkali, solvent or cleaning routine without checking the full sample-contact conditions first.
Use a gentle, non-abrasive cleaning approach suitable for laboratory optical glassware, and avoid cleaning methods that may scratch the optical faces. For broader background across cuvette constructions, see Compare fabrication options.
Included with this option
Supplied as a pack of four glass cuvettes. A closure is included with the pack.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, body geometry or a quartz alternative for another wavelength range, we can review a custom version. Send your drawing or labelled sketch, holder details, application range and target quantity through our contact page and refer to part number C302CE8.