Site Navigation

(MQQFL011) Quartz Fluorescence Cuvette, 6 mm path, 1.2 mL nominal capacity, Narrow Square Footprint

Weight50 g
SKU: MQQFL011

$359.00

In Stock

MQQFL011 is a JGS1 quartz fluorescence cuvette with a 6 mm optical path, 1.2 mL nominal capacity and an open-top chamber. Its narrow 8.5 × 8.5 × 45 mm body and five-sided optical windows suit setups that need direct filling from above and optical access from multiple sides. The listed price is for 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFL011 is a JGS1 quartz fluorescence cuvette with an open top, a 6 mm optical path and a narrow square body. It combines a 1.2 mL nominal capacity with five-sided optical windows in an 8.5 × 8.5 × 45 mm format, making it useful when you need direct access to the sample and more than one optical approach around the sample region.

Path Length
6 mm
Sample Volume (Nominal)
1.2 mL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeFluorescence Cuvette
Measurement ModeFluorescence Spectroscopy
Path Length6 mm
Light Transmission ConfigurationFive-Sided Optical Windows
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)1.2 mL
External Dimensions8.5 × 8.5 × 45 mm
Body Height45 mm
Base Dimensions8.5 × 8.5 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodMolded 83
Opening ConfigurationOpen Top
Pack Quantity1 Piece
Package Contents1 × Quartz Fluorescence Cuvette

Choose this option

Choose this cuvette when your fluorescence setup needs top filling together with side optical access in a narrow body. The open-top chamber allows direct pipetting and visual checking of the liquid, while the five-sided optical window layout gives added freedom when arranging excitation and collection directions around the cuvette.

What makes this option different

  • 6 mm optical path for fluorescence measurements using this defined path length.
  • Open-top chamber for direct filling and visual access to the sample.
  • Five-sided optical windows for measurement geometries that use multiple optical sides around the sample region.
  • Narrow 8.5 × 8.5 × 45 mm body with 1.2 mL nominal capacity.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Fill the sample from the open top and keep the cuvette in a consistent orientation for blank and sample readings. Before measurement, make sure the liquid fully covers the illuminated and observed region, and remove bubbles from the optical area.

The five-sided optical window layout provides multiple optical access faces, but it does not by itself determine instrument compatibility. Use the 1.2 mL value as the nominal capacity of the cuvette, not as a minimum working volume.

First-use check

  1. Inspect the optical faces and top opening before first use.
  2. Place the cuvette in the holder with a suitable blank and verify the excitation and collection alignment.
  3. Remove bubbles and exterior droplets, then repeat the background in the same orientation.

Fit and optical alignment

View the English selection reference.

The body measures 8.5 × 8.5 × 45 mm. Check holder clearance, beam position and access above the cuvette for pipetting or filling before ordering, especially if your instrument was designed around a larger square fluorescence cell.

No Z Height is established for this SKU. If your instrument depends on a defined beam-center height, compare the holder reference with the actual sample region before purchase.

English selection reference
Selection reference ↗

Solvents and cleaning

This cuvette uses Molded 83 quartz construction. This fabrication is commonly selected for organic-solvent methods and applications that may involve temperature, but suitability still depends on the actual liquid, exposure time and cleaning routine.

Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaners, and clean the optical faces gently with non-abrasive optical tissue. For aggressive chemicals, heated use or prolonged soaking, check the full conditions before use.

Included with this option

1 Quartz Fluorescence Cuvette.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We can review custom JGS1 quartz versions for changes to path length, nominal capacity, body dimensions, optical access, top opening details and beam-height requirements. Send a drawing or labelled sketch together with holder information, sample conditions and required quantity. Send a product-selection enquiry with SKU MQQFL011.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFL011) Quartz Fluorescence Cuvette, 6 mm path, 1.2 mL nominal capacity, Narrow Square Footprint”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare