(MQQLW003) Quartz Large-Window Cuvette, 5 mm path, 7 mL nominal capacity, Broad Optical Window
$162.00
MQQLW003 is a JGS1 quartz large-window cuvette for UV/Vis work that combines a 5 mm optical path with direct open-top access and a notably slim 7 mm body thickness. Its 7 mL nominal capacity and long rectangular format suit transmission measurements where you want straightforward filling but need to watch holder clearance. Sold as 1 piece per listed price.
Description
MQQLW003 is a JGS1 quartz large-window cuvette for UV/Vis measurements with a 5 mm optical path, Two-Way Light layout and 7 mL nominal capacity. Its open-top rectangular body gives direct access to the sample chamber, while the 45 × 7 × 45 mm outer size provides a broad optical face in a notably slim 7 mm profile. The listed price is for one cuvette.
- Path Length
- 5 mm
- Sample Volume (Nominal)
- 7 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Large-Window Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 5 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 7 mL |
| External Dimensions | 45 × 7 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 45 × 7 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top |
| Wall Thickness | 1 mm |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Rectangular Sample Cell |
Choose this option
Choose MQQLW003 when you need a 5 mm transmission path in a large-window style cell but have limited space across the holder thickness. The open top is useful for direct filling, rinsing and visual access during routine UV/Vis handling, and the slim body can be easier to place where side clearance is tighter than front-face support space.
What makes this option different
- Open-top sample access lets you fill, empty and rinse the chamber directly from above without working through a stopper or threaded closure.
- 5 mm optical path suits methods built around a shorter transmission distance than a 10 mm cell while keeping a rectangular large-window format.
- 7 mL nominal capacity gives a relatively deep sample region for this narrow-body style; use it as a chamber capacity figure rather than a minimum fill requirement.
- 45 × 7 × 45 mm outer body combines a long optical face with a notably slim thickness, so holder clearance across the 7 mm side is an important fit point.
- Two-Way Light layout supports straight transmission through the opposing optical faces for UV/Vis measurement.
- Fused-integrated construction is the supplier’s stated construction term for this exact SKU, paired here with a one-piece open-top body layout for routine filling and cleaning without a separate plate assembly.
Structure and dimensions

Using this cell
Fill the chamber from the top and keep the same orientation for blank and sample readings. The open-top layout makes it easier to add liquid directly and to rinse the chamber between runs, but it is not a sealed format.
Before measurement, make sure the liquid level fully covers the beam area in your own setup. The 7 mL figure is the nominal capacity of the cell, not a stated minimum working volume.
After filling, clear bubbles from the optical path and wipe exterior droplets from the outside surfaces. Handle the cuvette by non-optical areas where possible to keep the transmitting faces clean.
First-use check
- Inspect the optical faces and chamber edges for chips, residue or transit marks.
- Place the cell in the holder and confirm that the body is supported evenly without side stress.
- Run a blank in the intended orientation and verify that the beam passes through the selected transmission direction.
Fit and optical alignment
View the English selection reference.
The external body dimensions are 45 × 7 × 45 mm. In practical fitting, the 7 mm thickness is often the first dimension to check for holder clearance, while the 45 mm body length and height affect how the cell is supported and how much top access you have for filling.
Z Height is not established for this SKU. If your instrument or holder depends on a defined beam center height, please check that requirement before ordering rather than relying on outer dimensions alone.

Solvents and cleaning
The cell body is quartz. Detailed chemical limits for this exact SKU are not established here, so if your method uses aggressive chemicals, elevated temperature or long contact times, check the actual liquid and cleaning conditions before ordering.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials. For general guidance on cuvette construction approaches, see Fabrication Method of Cuvettes.
Included with this option
1 Quartz Rectangular Sample Cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz cuvettes for projects that need different path lengths, body dimensions, chamber volumes, window arrangements, openings or tolerance requirements. Send your drawing or holder details, sample conditions and target quantity for review.
Send a product-selection enquiry and quote SKU MQQLW003.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.










Reviews