(MQQPA003) Glass Particle Analysis Cell, Square Optical Chamber

Weight50 g
SKU: MQQPA003

$35.00

In Stock

Glass particle analysis cell with a 10 mm optical path, Four-Way Light access and an open top with flat lid. This Standard 80 adhesive-bonded version has a 3500 µL nominal volume for visible-light particle analysis from 350 nm upward. The listed price is for 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQPA003 is a glass Particle Analysis Cell for visible-light particle analysis from 350 nm upward. It combines a 10 mm optical path, Four-Way Light access and an open-top square body with a flat lid, so you can fill directly from above while keeping optical access on four sides. This version uses adhesive-bonded Standard 80 fabrication, and the supplier labels it as not acid- or alkali-resistant.

Path Length
10 mm
Sample Volume (Nominal)
3.5 mL
Opening Configuration
Open Top

Selection Specifications

Product KindSpecialized Cell
Cell TypeParticle Analysis Cell
Measurement ModeParticle Analysis
Path Length10 mm
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit350 nm
Sample Volume (Nominal)3.5 mL
External Dimensions12 × 12 × 45 mm
Body Height45 mm
Base Dimensions12 × 12 mm
MaterialGlass
MQ GradeStandard 80
Closure TypeFlat Lid
Closure IncludedYes
Fabrication MethodStandard 80
Opening ConfigurationOpen Top
Pack Quantity1 Piece
Package Contents1 × Glass Particle Analysis Cell; Accompanying closure

Choose this option

Choose this cell when your method needs a 10 mm particle analysis cell with four-side optical access and direct top filling, and when a single-cell sale unit suits your setup. The body geometry matters here as well: the 12 × 12 mm square section and 45 mm height need to fit your holder, and the chemical limitation is important if your sample or cleaning routine includes acidic or alkaline liquids.

What makes this option different

  • 10 mm optical path for particle analysis methods built around this path length.
  • Four-Way Light configuration provides optical access on four sides of the cell body.
  • Open top with flat lid allows direct filling and covered handling after loading.
  • Standard 80 adhesive-bonded construction with a supplier no acid- or alkali-resistance warning for this ordinary version.

Using this cell

Fill the cell from the top opening and place the flat lid after loading if your procedure calls for covered use. Before measurement, check that the optical faces are clean and that no visible bubbles remain in the light path.

Use the same orientation for blank and sample runs. In particle analysis work, sample preparation and exterior cleanliness remain part of the method, so keep dust, residue and droplets off the optical faces before placing the cell in the holder.

First-use check

  1. Inspect the optical faces, top opening and lid seating surfaces before first use.
  2. Place the cell in the holder and verify stable seating without interference.
  3. Run a suitable blank in the same orientation planned for sample measurement.

Fit and optical alignment

View the English selection reference. Also available in the product gallery.

The body dimensions are 12 × 12 × 45 mm. Check holder clearance against this actual body size and confirm that the top opening remains accessible in your fixture.

If your instrument uses a fixed beam centerline, check beam height separately before ordering, because Z Height is not established for this SKU. If you are replacing another cell, compare the holder contact points and beam position with your current part rather than relying on family resemblance alone.

English selection reference
Selection reference ↗

Solvents and cleaning

This option uses glass with adhesive-bonded Standard 80 construction. It is suited to methods where both the sample and the cleaning routine are compatible with this construction.

The supplier labels this ordinary glass cell as not acid- or alkali-resistant. Avoid acidic or alkaline exposure for routine use, and also avoid hydrofluoric acid, hot strong alkalis and abrasive cleaners. If your method involves unfamiliar chemicals, extended contact time or more aggressive cleaning, check the suitability of the complete cell-and-closure assembly before use.

Included with this option

1 Glass Particle Analysis Cell with an accompanying closure. The listed price is for 1 piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Send a product-selection enquiry with SKU MQQPA003, your holder details, sample conditions and required quantity.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQPA003) Glass Particle Analysis Cell, Square Optical Chamber”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare