(MQQPA004) Glass Particle Analysis Cell, Square Optical Chamber, Pack of 2
$66.00
Glass particle analysis cell pack with two cells, each with a 10 mm optical path, Four-Way Light access and an open top with flat lid. This Standard 80 adhesive-bonded version has a 3500 µL nominal volume per cell for visible-light particle analysis from 350 nm upward. The listed price is for a pack of 2.
Description
MQQPA004 supplies two glass Particle Analysis Cells in the selected sale unit. Each cell combines a 10 mm optical path, Four-Way Light access and an open-top square body with a flat lid, giving you direct top filling and optical access on four sides. This ordinary version uses adhesive-bonded Standard 80 fabrication, and the supplier labels it as not acid- or alkali-resistant.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Particle Analysis Cell |
| Measurement Mode | Particle Analysis |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 12 × 12 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 12 × 12 mm |
| Material | Glass |
| MQ Grade | Standard 80 |
| Closure Type | Flat Lid |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
| Sales Unit | pack of 2 |
| Package Contents | 2 × Glass Particle Analysis Cell; Accompanying closures |
Choose this option
Choose this pack when your setup needs this exact 10 mm four-side particle analysis cell format and you want two cells supplied together. The important selection points are the actual 12 × 12 mm square body, the open-top loading style and the chemical limitation of this ordinary version, since all three affect whether the cell suits your holder, handling routine and sample conditions.
What makes this option different
- Pack of 2 with the listed price applying to two cells.
- 10 mm optical path for methods designed around this path length.
- Four-Way Light configuration provides optical access on four sides of each cell.
- Standard 80 adhesive-bonded construction with a supplier no acid- or alkali-resistance warning for this ordinary version.
Using this cell
Fill each cell from the open top and place the flat lid after loading if your procedure uses covered handling. Keep the optical faces clean, remove visible bubbles before measurement and use the same orientation from blank to sample runs.
If you intend to use one cell for blank work and one for samples, keep the handling routine consistent between them. Exterior droplets, dust or residue on the optical faces can interfere with the optical path even when the sample fill is correct.
First-use check
- Inspect both cells, the optical faces and the lid seating areas before use.
- Confirm that each cell sits stably in the holder without interference.
- Run a suitable blank in the same orientation you plan to use for measurement.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
Each cell body is 12 × 12 × 45 mm. Check holder clearance and top access against this body size, especially if your fixture is tight around the opening or lid area.
If your instrument uses a fixed optical centerline, check beam position separately before ordering, because Z Height is not established for this SKU. This pack quantity does not by itself establish an optically matched pair, so check that point separately if your method requires it.

Solvents and cleaning
This option uses glass with adhesive-bonded Standard 80 construction. It is suited to methods where both the sample and the cleaning routine are compatible with this construction.
The supplier labels this ordinary glass cell as not acid- or alkali-resistant. Avoid acidic or alkaline exposure for routine use, and also avoid hydrofluoric acid, hot strong alkalis and abrasive cleaners. If your method includes unfamiliar chemicals, extended contact time or stronger cleaning conditions, check the suitability of the complete cell-and-closure assembly before use.
Included with this option
2 Glass Particle Analysis Cells with accompanying closures. The listed price is for the pack of 2.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the critical dimensions and tolerances for your application. Send a product-selection enquiry with SKU MQQPA004, your holder details, sample conditions and required quantity.
Additional information
| Weight | 50 g |
|---|