(C0.52CS) Quartz Standard Cuvette, 0.5 mm Path, 175 µL
Original price was: $79.00.$72.00Current price is: $72.00.
C0.52CS is a JGS1 quartz standard cuvette with a 0.5 mm optical path, Two-Way Light geometry and 175 µL nominal capacity. This open-top version is supplied without a closure and is intended for direct filling with neutral solutions.
Description
C0.52CS is a JGS1 quartz standard cuvette for short-path measurements using a 0.5 mm optical path and a two-way light layout. Its 175 µL nominal capacity and open-top body make it straightforward to fill by pipette in a compact standard-cell format. This supplied version has no closure, and the stated chemical-use limit is neutral solutions.
- Path Length
- 0.5 mm
- Sample Volume (Nominal)
- 175 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 0.5 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 175 µL |
| External Dimensions | 3 × 12.5 × 45 mm |
| Cell Body Dimensions | 3 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | No Closure |
| Closure Included | No |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C0.52CS when you need a 0.5 mm path in a standard quartz cuvette and your sample routine stays within neutral-solution use. The open top gives direct access to the chamber, while the 3 × 12.5 × 45 mm body-only geometry is the size to check where holder fit and top clearance matter.
What makes this option different
- 0.5 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Two-Way Light: align the opposing optical faces with the transmission beam and use the same orientation for blank and sample readings.
- 175 µL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Closure not included: plan the sample-loading procedure around the supplied cell configuration and specify any required cover separately.
Using this cell
Load the sample from the open top and fill so the beam passes through a fully covered liquid region. The 175 µL figure is the nominal capacity of the cell, not a minimum working volume, so your method may require a different practical fill level depending on beam position and handling.
Because no closure is supplied, this version is best suited to direct filling and measurement in an open chamber rather than a sealed handling routine. Keep the optical faces clean by holding the cell on non-optical outer surfaces and removing bubbles before measurement.
First-use check
- Inspect the cuvette and its optical faces for chips, residue or transit damage.
- Test the empty cell in your holder before preparing samples.
- Run a blank in the same orientation you plan to use for measurements.
Fit and optical alignment
The stated 3 × 12.5 × 45 mm dimensions apply to the cell body only. Use them to check holder width, seating depth and vertical clearance in your instrument or adapter.
Z Height is not established for this exact SKU, so do not assume beam-height compatibility from the path length alone. Two-Way Light describes the opposing transmission direction through the cell and should not be treated as proof of fit with a specific instrument.
Solvents and cleaning
This option is described for use with neutral solutions. If your sample, rinse or cleaning routine involves acidic, alkaline or organic media, review the suitability of the full wetted assembly before use rather than assuming broader compatibility.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Wipe the exterior optical faces gently with non-abrasive optical tissue. For general fabrication background, see Compare fabrication options.
Included with this option
No closure is included with this configuration. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Discuss your requirements and quote part number C0.52CS.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews