(C102CS82) Quartz Micro Cuvette, 10 mm Path, 700 µL
Original price was: $29.00.$27.00Current price is: $27.00.
C102CS82 is a black-wall JGS1 quartz micro cuvette for UV/Vis spectroscopy, with a 10 mm optical path, 700 µL nominal capacity and a 2 mm sample-region width. Its Two-Way Light layout keeps the optical path on the main measurement faces, and this sale unit is 1 cuvette with a closure included.
Description
C102CS82 is a black-wall JGS1 quartz micro cuvette for UV/Vis spectroscopy when you need a 10 mm path with more sample-region width and nominal capacity than the narrower 1 mm version. This option combines a 700 µL nominal capacity with a 2 mm sample-region width in the same compact outside format. The listed sale unit is 1 cuvette, with a closure included.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 700 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 2 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Detection Channel Width | 2 mm |
Choose this option
Choose C102CS82 when your method uses a standard 10 mm absorbance path but you want a 2 mm sample region instead of a narrower slit-style zone. The 700 µL nominal capacity and black-wall, Two-Way Light format make this a practical choice for UV/Vis setups that need a compact cell while still giving a broader filled measurement region within the micro-cuvette body.
What makes this option different
- 10 mm optical path for standard absorbance methods.
- 700 µL nominal capacity in a micro cuvette format.
- 2 mm sample-region width for a broader filled zone than the 1 mm version.
- Black-wall, Two-Way Light layout with transmission through the main optical faces only.
- Sale unit: 1 cuvette with a closure included.
Using this cell
Fill the cell so the illuminated region is fully covered during measurement. The 700 µL figure is the nominal capacity, not a minimum working volume, so the practical fill level depends on your beam position, beam footprint and measurement setup.
Use the same orientation for blank and sample measurements, and keep bubbles out of the beam area. Clean the optical faces and the sample region carefully between runs so residue does not remain across the light path.
First-use check
Inspect the cell on arrival, rinse it with a cleaning liquid suitable for your method, and test-fit the empty body in your holder. A blank run is a practical first check for seating, beam position and fill coverage before sample use.
Fit and optical alignment
The uncapped cell dimensions are 12.5 × 12.5 × 45 mm. These dimensions apply to the bare cuvette body, so check holder opening, seating depth and any top clearance needed for the closure if it will remain in place during handling or measurement.
Z Height is not listed for this option. The 2 mm sample-region width is relevant to beam placement, so if your instrument depends on a defined beam-center height or tightly fixed beam position, verify that fit before ordering.
Solvents and cleaning
This cuvette uses Standard 80 adhesive-bonded quartz construction. It is suited to routine water-based samples and buffers at room temperature. Avoid organic sample solvents and organic cleaning agents with this construction.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods. For routine handling, rinse promptly after use and wipe the optical faces gently with non-abrasive optical-surface wipes.
Included with this option
Price is for 1 cuvette. A closure is included with this option.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows, Z Height, closure details and fabrication requirements. Send a labelled drawing or sketch, together with your holder or instrument details, application wavelength range, sample conditions and target quantity through the contact page, and refer to part number C102CS82.
Additional information
| Weight | 30 g |
|---|