(C102SS35) Quartz Micro Cuvette, 10 mm Path, 350 µL
Original price was: $76.00.$69.00Current price is: $69.00.
C102SS35 is a JGS1 quartz micro cuvette for UV/Vis work with a 10 mm optical path, Two-Way Light geometry and a 1 mm sample-region slit. Its 350 µL nominal capacity, supplied stopper and neutral-solution-only restriction make it suitable for tightly defined small-volume methods that already stay within that chemical condition. Sold as 1 cuvette per listed price unit.
Description
C102SS35 is a JGS1 quartz micro cuvette for UV/Vis measurements with a 10 mm optical path and a narrow 1 mm sample region. Its 350 µL nominal capacity makes it a small-volume option in this group, and the supplied stopper supports closed handling for methods that use neutral solutions only.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 1 mm |
| Sample Volume (Nominal) | 350 µL |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 1 mm |
Choose this option
Choose C102SS35 when your method calls for a 10 mm path length but uses a narrow 1 mm illuminated sample region and a small nominal fill volume. The neutral-solution-only restriction is a key part of selection for this item, so it fits best where both the sample and routine rinsing stay within that condition.
What makes this option different
- 10 mm optical path for standard UV/Vis absorbance measurements.
- 1 mm sample-region slit for a narrow defined illuminated section.
- 350 µL nominal capacity in a micro cuvette format.
- Neutral solutions only for sample handling and routine use under the stated restriction.
Using this cell
Load the sample carefully so the liquid fully covers the beam path and no bubbles remain in the illuminated region. Keep the same orientation and seating for blank and sample, and insert the stopper gently after filling.
The 350 µL nominal capacity is useful for planning sample preparation, but it is not a minimum working volume specification. If your method runs close to the available fill height, verify that the beam is fully covered during measurement.
First-use check
Before first use, inspect the optical faces and opening for chips, dust or residue. Rinse with a neutral, method-compatible liquid, fill with a blank, and confirm stable placement and a clear optical path before running samples.
Fit and optical alignment
This is a Two-Way Light micro cuvette, so the beam passes through the two optical faces along the 10 mm path. The stated 1 mm slit describes the sample-region width and matters when your instrument uses a tightly defined beam footprint.
Z Height is not specified for this SKU. If your spectrometer holder has a fixed beam center or limited clearance, check compatibility before ordering and send the holder details if you would like a fit review.
Solvents and cleaning
This option is restricted to neutral solutions only. Apply the same restriction to rinsing and cleaning liquids, and do not select this cuvette for acidic, alkaline or otherwise incompatible chemical conditions.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces gently with non-abrasive optical tissue. For background on MQ fabrication options, see Compare fabrication options.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions related to optical path length, sample volume, optical windows, Z Height, closures and fit details. Send a dimensioned drawing or labelled sketch, your holder or instrument information, the sample conditions and the required quantity. Discuss your requirements and quote part number C102SS35.