(C102SS16) Quartz Micro Cuvette, 10 mm Path, 700 µL
Original price was: $72.00.$65.00Current price is: $65.00.
C102SS16 is a JGS1 quartz micro cuvette for UV/Vis spectroscopy with a 10 mm optical path, 700 µL nominal capacity and Two-Way Light transmission layout. Its narrow 2 mm sample-region width suits methods that need a compact filled region in a small square cuvette body. Supplied as 1 cuvette per price unit, with a stopper included.
Description
C102SS16 is a quartz micro cuvette for UV/Vis work when you need a standard 10 mm optical path in a smaller-volume format. This JGS1 cell combines a 700 µL nominal capacity with a narrow 2 mm sample region and a stopper-equipped top, so it is well suited to straight-through measurements where beam size, fill level and holder fit all matter together.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 700 µL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 2 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Detection Channel Width | 2 mm |
Choose this option
Choose C102SS16 when your method needs a 10 mm transmission path but you want a micro cuvette body rather than a larger full-size cell. The 700 µL nominal capacity and 2 mm sample-region width make this option useful where the illuminated region should stay within a relatively narrow filled section, while the included stopper keeps the opening covered during normal bench handling.
What makes this option different
- 10 mm optical path for standard straight-through UV/Vis measurement geometry.
- 700 µL nominal capacity in a compact micro cuvette format.
- 2 mm stated sample-region width for methods that use a narrow filled measurement zone.
- Two-Way Light layout with a stopper included for covered sample handling.
Using this cell
Fill the cuvette so the illuminated sample region is fully covered during the measurement, and keep bubbles and droplets away from the optical faces. Use the same orientation for blank and sample runs to keep the beam path consistent.
The 700 µL figure is the nominal capacity of the cell, not a minimum working volume. The stopper helps close the top during routine use, but this product is not presented here as a pressure-rated or transport-rated container.
First-use check
- Rinse the cell with a liquid that is suitable for your method.
- Inspect the optical faces for dust, residue or scratches.
- Place the cuvette in your holder and verify stable seating.
- Run a blank and confirm that the beam passes cleanly through the filled sample region.
Fit and optical alignment
The stated external size is 12.5 × 12.5 × 45 mm, with a 12.5 × 12.5 mm base. This helps you check holder opening and top clearance, especially in compact cuvette compartments.
Z Height is not stated for this exact option, so outer dimensions alone should not be used to assume beam-center alignment. The stated 2 mm window/sample-region width is helpful for beam-fit planning, but it should not be treated as a certified clear aperture or an instrument slit setting.
Solvents and cleaning
This cuvette uses Standard 80 adhesive-bonded quartz construction. It is generally suited to routine room-temperature water-based samples and buffers.
Avoid organic samples and organic cleaning solvents with this adhesive-bonded cell. Do not use hydrofluoric acid on quartz, and avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive optical tissue or other non-abrasive laboratory wipes.
Included with this option
Supplied as 1 micro cuvette. A stopper is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch together with your holder or instrument information, critical dimensions, sample conditions and target quantity. You can start the discussion here: Discuss your requirements.
Additional information
| Weight | 30 g |
|---|