(C102SS34) Quartz Stoppered Cuvette, 10 mm Path, 1.4 mL
Original price was: $86.00.$78.00Current price is: $78.00.
C102SS34 is a JGS1 quartz stoppered cuvette with a 10 mm optical path, Two-Way Light layout, 1.4 mL nominal capacity and a 4 mm sample-region channel. It suits UV/Vis work from 200 to 2500 nm when you want a covered micro-volume cell with a wider sample region than the narrower slit options while keeping the same 10 mm transmission path. Supplied as 1 cuvette with stopper included.
Description
C102SS34 is a JGS1 quartz stoppered cuvette for UV/Vis measurements from 200 to 2500 nm. It combines a 10 mm optical path with a 1.4 mL nominal capacity and a 4 mm sample-region channel, making it the wider-channel option within this covered micro-volume style. The included stopper keeps the sample chamber covered during routine handling, and the listed price is for 1 cuvette.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.4 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Stoppered Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.4 mL |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Detection Channel Width | 4 mm |
Choose this option
Choose C102SS34 when your method uses a 10 mm path and you want a stoppered quartz cell with a wider sample-region channel in this series. The 4 mm channel and 1.4 mL nominal capacity make this option a practical fit when you prefer more sample space in the measurement region while keeping the compact body format and covered access of a stoppered cell.
What makes this option different
- 10 mm optical path for methods built around that path length.
- 1.4 mL nominal capacity in a compact micro-volume format.
- 4 mm sample-region channel for this exact selected geometry.
- Two-Way Light layout for transmission through one opposing window pair.
- JGS1 quartz body for UV/Vis use from 200 to 2500 nm.
- Stopper included for covered loading and handling.
Using this cell
Fill the cuvette so the liquid fully covers the beam region used by your instrument, then seat the stopper gently. Keep the same orientation for blank and sample, and make sure the optical faces are free from droplets, fingerprints and residue before measurement.
The stated 1.4 mL is nominal capacity. Minimum working volume is not established for this SKU, so if your method depends on lower fills or a specific liquid height over the beam, that should be checked in your own setup.
First-use check
- Inspect the optical faces and sample region for chips, residue or visible contamination.
- Rinse with a suitable blank or cleaning liquid for your method.
- Test the cuvette in the holder and confirm that the beam passes through the filled measurement region.
- Insert the stopper gently and check that it seats cleanly.
Fit and optical alignment
The body height is 45 mm and the base is 12.5 × 12.5 mm, which helps with holder clearance checks in compact compartments. The Two-Way Light layout keeps the optical use to the main measurement direction rather than to side-access arrangements.
Z Height is not stated for this option, and the body height does not establish the overall height with the stopper in place. If your holder depends on a defined beam-center height or has limited clearance above the cuvette, please confirm those points before ordering.
Solvents and cleaning
This cuvette uses Standard 80 adhesive-bonded quartz construction. For routine selection, that makes it best suited to room-temperature water-based samples and buffers. Avoid organic samples and organic cleaning solvents with this adhesive-bonded cell.
Detailed chemical limits for the selected stopper-and-cell assembly are not stated here, so check the full sample and cleaning conditions if your method involves aggressive solvents, elevated temperature or long contact time. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces with non-abrasive laboratory or optical tissue.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions if you need changes to path length, body size, sample volume, windows, Z Height, closure details or tolerance requirements. Send your drawing or holder information, the dimensions that matter most, your sample conditions and the required quantity.
Contact us and mention SKU C102SS34 for a custom review.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.