(C104SS21) Quartz Stoppered Cuvette, 10 mm Path, 3.5 mL
Original price was: $119.00.$108.00Current price is: $108.00.
C104SS21 is a JGS1 quartz stoppered cuvette with a 10 mm optical path, Four-Way Light access and 3.5 mL nominal capacity for fluorescence spectroscopy. The stoppered top gives you controlled sample access, while the four-way optical layout suits measurement setups that need side optical access around a standard 10 mm path. Sold as 1 cuvette per listed price unit.
Description
C104SS21 is a JGS1 quartz stoppered cuvette for fluorescence spectroscopy, combining a 10 mm optical path with Four-Way Light access and a 3.5 mL nominal sample region. This format suits methods that need a closed-top cell with direct filling through the top opening, while keeping side optical access around the sample for compatible fluorescence measurement geometry.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Stoppered Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.5 mL |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
Choose this option
Choose C104SS21 when you want a standard 10 mm path in a stoppered quartz cell rather than an open-top chamber. The stoppered access helps with filling, handling and covering the sample between steps, and the 3.5 mL nominal capacity places it in a regular cuvette-scale format rather than a micro-volume design. Its supplier-described fused integrated construction is useful when you want this stoppered body style and optical layout in one assembled quartz cell.
What makes this option different
- Stoppered top access lets you fill and handle the sample through a defined opening instead of using an open chamber.
- Four-Way Light access supports side optical entry and observation paths used in compatible fluorescence setups.
- 10 mm optical path keeps the familiar standard path length while using a stoppered fluorescence-cell format.
- 3.5 mL nominal capacity suits routine cuvette-scale liquid loading rather than micro-volume work.
- JGS1 quartz body supports use across the stated 200–2500 nm wavelength range.
- Supplier-described fused integrated construction identifies this as an assembled quartz cell body rather than a loose cover-plate style sample holder.
- 12.5 × 12.5 mm base with 45 mm body height helps you check holder seating and vertical clearance for the bare cell body.
Using this cell
Fill the cell through the top opening according to your method, then seat the stopper as required by your procedure. For fluorescence work, make sure the liquid level covers the part of the sample region used by your beam geometry, and remove visible bubbles before measurement.
Keep the same cell orientation for blank and sample so the optical path and side access stay consistent. The 3.5 mL figure is the nominal capacity of the cell, not a minimum working volume, so very low-fill methods should be checked in the actual instrument setup.
First-use check
Before routine use, inspect the optical faces for dust, residue or handling marks, and confirm that the cell sits squarely in your holder. Run a blank with your intended liquid and check that your fill level, stopper arrangement and beam position work together without trapping bubbles in the measurement region.
Fit and optical alignment
The supported body dimensions for this SKU are a 12.5 × 12.5 mm base and 45 mm body height for the bare cell body. These are the practical dimensions to check for holder seating and body clearance.
If your instrument has a fixed beam-center position or limited vertical clearance, confirm Z Height and alignment; body size alone does not establish beam fit.
Solvents and cleaning
Use normal careful cleaning practice for quartz optical cells, and match your sample and cleaning method to the complete wetted assembly used in your procedure. Keep hydrofluoric acid away from quartz, avoid hot strong alkalis and abrasive cleaning, and wipe optical faces gently with non-abrasive optical tissue.
For general background on cuvette construction approaches, see cuvette fabrication methods.
Included with this option
1 cuvette per listed price unit. If your setup requires a particular stopper, confirm that it is included with your order.
Availability and ordering
Order this listed specification directly, or ask about current availability and dispatch. If your delivery date is important, ask before checkout; preparation or production time is separate from transit and customs clearance.
Discuss a custom version
If you need a different optical path, body geometry or holder fit, send a drawing or describe the change you need. Custom JGS1 quartz enquiries are assessed separately from this listed specification, with feasibility, quantity, price and production time confirmed in the project quotation.
Design notes for this configuration: Stoppered Fluorescence Cuvette: Specifying the Opening and Closure Fit
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.