(C102CS72) Quartz Ultra-Micro Cuvette, 10 mm Path, 100 µL
Original price was: $124.00.$112.00Current price is: $112.00.
C102CS72 is a JGS1 quartz ultra-micro cuvette with a 10 mm optical path, 100 µL nominal capacity and an open top for direct filling. This Two-Way Light version combines a 2 × 5 mm optical window area with an 8.5 mm Z Height for small-volume UV/Vis setups that need a defined beam position. Sold per 1 cuvette.
Description
C102CS72 is an ultra-micro quartz cuvette for small-volume UV/Vis work where both beam position and body fit need to be checked before use. It combines a 10 mm optical path with a 100 µL nominal capacity, a 2 × 5 mm optical window area and an 8.5 mm Z Height in a 12.5 × 12.5 × 45 mm body. The open top gives direct access for pipette loading, rinsing and visual inspection of the sample region.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 100 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Z Height | 8.5 mm |
| Optical Window Dimensions | 2 × 5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 100 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
Choose this option
Choose C102CS72 when you need a compact 10 mm path cell but your method still depends on a defined low beam center and a small illuminated window area. The body dimensions help you check holder seating, while the open top suits direct loading rather than a closed-flow or pressure setup. Its JGS1 quartz construction is suitable for stated UV/Vis use across 200–2500 nm where this geometry fits your instrument.
What makes this option different
- 10 mm optical path in an ultra-micro format for methods that still require the standard path length.
- 100 µL nominal capacity for small sample volumes without changing to a shorter optical path.
- Open-top access for pipette filling, sample exchange and straightforward rinsing between runs.
- Two-Way Light layout for transmission measurements along the defined optical path.
- 2 × 5 mm optical window area to help you check whether your beam footprint fits the usable optical region.
- 8.5 mm Z Height for holders and instruments built around a specific beam-center height.
- 12.5 × 12.5 × 45 mm body for holder and compartment fit checks based on the cell body itself.
Using this cell
Load the sample from the top and keep the liquid level high enough to cover the optical path during measurement. The 100 µL figure is a nominal capacity, not a minimum working fill, so your actual fill level depends on how your beam sits within the sample region.
The open top is convenient for blanks, frequent sample changes and post-run rinsing. Handle the cell upright during use, and inspect the window area after filling so bubbles or droplets do not sit in the illuminated region.
First-use check
- Inspect the optical faces for chips, residue or handling marks.
- Place the empty cell in your holder to confirm body fit and beam position.
- Run a blank after filling to confirm the sample region covers the optical path cleanly.
Fit and optical alignment
The body measures 12.5 × 12.5 × 45 mm, and these dimensions apply to the cell body only. Check holder width, seating depth and top clearance against your instrument if the compartment is tight or if loading access is limited.
The optical center is 8.5 mm above the bottom reference. The stated 2 × 5 mm window area is also worth checking against your beam height and footprint, especially in instruments with fixed alignment and little vertical adjustment.
Solvents and cleaning
This cuvette uses Standard 80 adhesive-bonded quartz construction. For this type, routine room-temperature water-based samples and buffers are the normal selection direction. Avoid organic samples and organic cleaning solvents with this construction.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. After use, rinse promptly and clean the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. Contact us before ordering if you require a supplied closure or other accessory.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows, Z Height, openings and fabrication. Send a dimensioned drawing or labelled sketch together with holder details, critical dimensions, sample chemistry and quantity. You can discuss your requirements and quote part number C102CS72.
Additional information
| Weight | 30 g |
|---|