(C104CQE) Quartz Fluorescence Cuvette, 10 mm Path, 3.5 mL, Pack of 2
Description
C104CQE is a quartz fluorescence cuvette for methods built around a 10 mm optical path and optical access from four sides. Its 3.5 mL nominal capacity and open-top body make it easy to fill, inspect and handle in routine liquid-sample work, while the rectangular cuvette format remains familiar for standard holder layouts. This sale option is supplied as a pack of 2, with a closure included.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Closure Included | Yes |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C104CQE when you need a four-way fluorescence cell that can be filled directly from above and used in a 10 mm path setup. The open sample access is useful for pipetting, visual fill checks and straightforward rinsing between runs, and the 3.5 mL nominal capacity suits methods that work with a conventional cuvette volume rather than a micro-volume format.
What makes this option different
- 10 mm optical path for methods written around this path length.
- Four-Way Light layout for optical access through all four side faces.
- Open-top cell body for direct filling and visual inspection of the sample region.
- Pack of 2 for this MQ sale option, with closure included.
Using this cell
Fill the cell from the top and keep the optical faces clean and dry in the beam area before measurement. If your method is sensitive to bubbles, check the sample region after filling and allow the liquid to settle before placing the cell in the holder.
In fluorescence work, keep the same cell orientation between blank and sample runs when your setup uses defined excitation and collection directions. The stated 3.5 mL figure is a nominal capacity, not a minimum working volume, so the fill level still needs to suit your instrument geometry and measurement method.
First-use check
- Inspect the optical faces and rim for chips, residue or transport marks.
- Test the cell in your holder and check top clearance for the closure.
- Run a blank first and verify that the beam passes through a clean, fully filled sample region.
Fit and optical alignment
The listed dimensions are 12.5 × 12.5 × 45 mm for the cell body. These body dimensions are useful for checking holder seating and compartment space, especially if you plan to leave the closure in place during handling or measurement.
Z Height is not stated for this option. If your instrument uses a fixed beam height or a tight fluorescence holder, check beam position and vertical clearance before ordering rather than relying on body height alone.
Solvents and cleaning
Quartz is used for the cell body, but the chemical limits of this complete selected assembly are not established here. If your sample, rinse solvent or cleaning routine is chemically aggressive, check compatibility for the full use condition before ordering.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with suitable non-abrasive laboratory tissue, and see the general fabrication options overview if you are selecting for a specific solvent routine.
Included with this option
Supplied as 2 quartz fluorescence cuvettes in the selected sales pack. A closure is included with this option.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different body size, optical path, volume, opening style or holder fit, send your drawing or labelled sketch and note the dimensions that matter in your setup. Include your instrument or holder details, sample conditions and required quantity when you contact us.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.