(C022WS6) Quartz Flow Cell, 2 mm Path, 700 µL
Original price was: $251.00.$226.00Current price is: $226.00.
C022WS6 is a quartz flow cell for UV/Vis work with a 2 mm optical path, a Two-Way Light layout and 700 µL nominal capacity. It uses two opposed fluid tubes with 5 mm OD and 3 mm ID, which is an important connection detail for tubing choice and straight-run installation space. Supplied as the listed C022WS6 flow-cell specification.
Description
C022WS6 is a quartz flow cell for UV/Vis spectroscopy with a 2 mm optical path and a 700 µL nominal capacity. Its Two-Way Light layout and larger 5 mm OD / 3 mm ID opposed tube connections make it a useful choice when the flow connection size matters as much as the optical path.
The stated overall length for this version is 76 mm, which helps when checking straight-line clearance in the flow path and around the holder area. This item is identified for UV/Vis use, but the material grade and full external body cross-section are not listed here.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 700 µL
- Opening Configuration
- Two Opposed Fluid Tubes
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 2 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| Material | Quartz |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 5 mm |
| Tube Inner Diameter (ID) | 3 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | Two Opposed Fluid Tubes |
Choose this option
Choose C022WS6 when you need a short 2 mm transmission path in a simple in-line flow format and your setup is designed around 5 mm OD / 3 mm ID tube connections. It is especially relevant where the fluid connection size is part of the selection, because that affects tubing choice, support layout and the space needed on both sides of the cell.
What makes this option different
- 2 mm optical path in a Two-Way Light transmission layout.
- 700 µL nominal cell volume for planning fill and rinse steps.
- Two opposed fluid tubes with 5 mm OD and 3 mm ID.
- 76 mm stated overall length for checking straight-run clearance.
Using this cell
Install the cell inline using the two opposed tube connections and support it so the connection ends are not carrying the load of the tubing. Fill gradually and inspect the optical region before measurement to make sure the light path is free of bubbles and residual liquid.
Use the 700 µL figure as the nominal volume of the cell itself. If you are planning washout timing or sample changeover, include the volume of the connected tubing and any other wetted components in the same circuit.
First-use check
- Inspect the optical faces and tube ends before installation.
- Verify that your tubing matches the stated 5 mm OD / 3 mm ID connection size.
- Run a suitable blank and check the light path for bubbles or residue.
- Confirm that the cell is supported without bending stress on the tube connections.
Fit and optical alignment
The 76 mm overall length is the key published fit detail for this option. It helps you check the straight installation run and the clearance needed for tubing approach, but it does not define the full external body shape or holder cross-section.
Z Height is not listed for this model, and the external dimensions are not established here as a released fit specification. If your instrument has a fixed beam position or a tight mounting space, please confirm the required beam height and body clearance before ordering.
Solvents and cleaning
Molded 83 is commonly chosen for methods involving organic solvents and for applications that may involve temperature control. Choose cleaning and sample-contact materials for the full wetted path, including any connected tubing and fittings.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. After use, rinse promptly and clean the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
The listed price is for one C022WS6 flow cell.
Additional accessory contents should be confirmed for your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and include your holder or instrument details, sample conditions and target quantity. Discuss your requirements.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.







Reviews