(C022CF) Quartz Standard Cuvette, 2 mm Path, 700 µL
Original price was: $156.00.$141.00Current price is: $141.00.
C022CF is a JGS1 quartz standard cuvette for UV/Vis spectroscopy with a 2 mm optical path, Two-Way Light transmission and 700 µL nominal capacity. This Molded 0.01 version combines a compact short-path sample region with an included closure, making it useful when you need a 2 mm standard-body cell and want the top covered during routine handling.
Description
C022CF is a JGS1 quartz standard cuvette for UV/Vis spectroscopy with a 2 mm optical path, 700 µL nominal capacity and Two-Way Light transmission. Its compact 12.5 × 4.5 × 45 mm uncapped body suits holder-fit checks for short-path work, and a closure is included for routine top covering. This exact version uses Molded 0.01 fabrication.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 700 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 2 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 12.5 × 4.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 4.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 0.01 |
Choose this option
Choose C022CF when your method calls for a 2 mm path in a standard cuvette body and you want a covered top during normal handling rather than a fully open-only format. The 700 µL nominal capacity is part of that selection value: it gives you a short-path sample region in a compact body, so you can match the cell to a 2 mm UV/Vis method without stepping away from standard cuvette handling.
What makes this option different
- 2 mm optical path for UV/Vis methods that specify a short transmission path.
- Two-Way Light configuration for direct transmission through the main optical faces.
- 700 µL nominal capacity in this exact short-path format, helping you plan sample fill in a compact standard-body cell.
- Closure included so the top can be covered during routine transfer and bench handling.
- Molded 0.01 fabrication, useful when your purchasing or method setup distinguishes not only cell geometry but also the fabrication route used for this version.
- 12.5 × 4.5 × 45 mm uncapped body for checking holder seating before ordering, with extra top space allowed for the closure.
Using this cell
Fill the cell so the liquid fully covers the beam during measurement, and remove visible bubbles before reading. In this 2 mm / 700 µL combination, the short path and compact sample region make careful filling and consistent orientation important for blank and sample runs.
The included closure is useful for covering the sample during routine handling, but it should not be treated as a pressure-rated or leak-tight connection. Handle the cuvette by the non-optical faces to keep the optical surfaces clean.
First-use check
Before first measurement, inspect the optical faces under good light, rinse with a suitable cleaning liquid for your method, and verify that the cell seats squarely in your holder. Then run a blank at your working wavelength to confirm clean windows and stable placement.
Fit and optical alignment
The stated 12.5 × 4.5 × 45 mm dimensions apply to the uncapped cell body. Use those dimensions to check holder seating, slot width and installed clearance, then allow additional space above the cell for the included closure.
Z Height is not stated for this SKU. If your holder or instrument uses a fixed beam-center height or has limited top clearance, verify those details directly rather than assuming compatibility from the outer shape alone.
Solvents and cleaning
Molded 0.01 is the option to consider when your method calls for closely specified optical-path precision. For the 2 mm path on this cell, agree the required tolerance and measurement conditions for the order.
In practical terms, that is most relevant when your lab selects a 2 mm lidded cell not only by optical path and nominal volume, but also by the build designation specified in your method, purchasing standard or established cleaning routine.
Chemical limits for the complete cell assembly are not established here, including the closure materials and specific cleaning compatibility. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and check aggressive chemicals, heated solutions or long contact times before ordering.
Included with this option
The selected item is the C022CF cuvette with a closure included. Package quantity is not stated here, so please refer to the selected sales option if you need the order quantity clarified before purchase.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication requirements. Send a dimensioned drawing or labelled sketch, plus your holder details, wavelength range, sample conditions and target quantity. Discuss your requirements and quote part number C022CF.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews