(C302CE3) Quartz Large-Window Cuvette, 10 mm Path, 10.5 mL
Original price was: $114.00.$103.00Current price is: $103.00.
C302CE3 is a JGS1 quartz large-window cuvette for UV/Vis spectroscopy with a 10 mm optical path, Two-Way Light transmission layout and 10.5 mL nominal capacity. The open-top body gives direct access for filling, rinsing and visual sample checks from above.
Description
C302CE3 is a JGS1 quartz large-window cuvette for UV/Vis spectroscopy with a 10 mm optical path and 10.5 mL nominal capacity. Its open-top format gives direct access to the sample chamber for filling, rinsing and visual checks, while the larger body format suits methods that need a broader cell rather than a compact small-volume shape.
The optical layout is a straightforward Two-Way Light transmission arrangement for measurements across the stated 200–2500 nm range. If your method uses a standard 10 mm path and you want easier top access during sample loading or cleaning, this option combines those features in one cell.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 10.5 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Large-Window Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 10.5 mL |
| External Dimensions | 32.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 32.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C302CE3 when you need a 10 mm UV/Vis transmission cuvette with a larger nominal sample chamber and direct top access. The combination of open filling, a 10.5 mL nominal capacity and a broad large-window body is useful when you want straightforward manual loading and chamber inspection instead of working through a narrower format.
What makes this option different
- Open-top access lets you add sample, rinse the chamber and inspect the liquid surface directly from above.
- Closure included allows the filled cell to be covered during handling, but the closure style and sealing performance are not specified here.
- 10 mm optical path matches standard transmission methods without changing to a longer or shorter path format.
- 10.5 mL nominal chamber: gives direct access to a millilitre-scale liquid region for loading and visual checks; verify beam coverage at your intended fill level.
- Two-Way Light layout is suited to straight-through transmission measurements rather than side-access optical arrangements.
- Open chamber with accompanying closure: access the liquid directly for loading and rinsing, then cover the opening for routine handling; this does not establish a sealed assembly.
Using this cell
Fill the cell from the top opening and place it so the transmission faces align with the beam path. Before measurement, check that the liquid level covers the optical region used in your setup and remove visible bubbles or droplets from the beam area.
The stated 10.5 mL is a nominal capacity, not a minimum working volume. If your method uses a low fill level or a fixed beam position, verify liquid coverage in your holder before running samples.
First-use check
Inspect the cell for dust, fingerprints, edge damage or residue before first use. A blank measurement at your working wavelength and a trial fit in the holder are practical first checks before introducing sample.
Fit and optical alignment
The listed 32.5 × 12.5 × 45 mm dimensions apply to the body only. This helps when checking holder clearance for the cuvette body, but you should also leave space above the cell because the included closure is outside those body dimensions.
Z Height is not stated for this option. If your instrument has a fixed beam height or a tight holder opening, confirm that alignment requirement with the actual beam position rather than relying on body size alone.
Solvents and cleaning
This cuvette is a quartz UV/Vis cell. Do not use hydrofluoric acid on quartz, and avoid hot strong alkalis or abrasive cleaning methods that can mark or damage the optical faces.
Detailed chemical compatibility limits are not established here for this exact option. If your samples or cleaning steps involve aggressive solvents, elevated temperature or extended contact time, review those conditions before use. For general MQ construction background, see fabrication options.
Included with this option
The listed price is for 1 C302CE3 cuvette, with an accompanying closure and storage box.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz cuvette projects for changes involving dimensions, optical path length, sample volume, optical windows, Z Height, closures, connections and related application requirements. Discuss your requirements and quote part number C302CE3.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.