(C304CR5) Quartz Rectangular Sample Cell, 30 mm Path
Original price was: $190.00.$171.00Current price is: $171.00.
C304CR5 is a JGS1 quartz rectangular sample cell with a 30 mm optical path, Four-Way Light access and an open-top square chamber for UV/Vis work. The open sample region gives direct top access for filling, rinsing and visual inspection, while the four-side optical layout supports side-face beam access around the cell body. Sold as 1 cell.
Description
C304CR5 is a JGS1 quartz rectangular sample cell for UV/Vis spectroscopy with a 30 mm optical path and an open-top square chamber. It suits setups that need direct top access for loading and rinsing, while keeping optical access through all four side faces in one compact body. This listing is for 1 cell.
- Path Length
- 30 mm
- Cell Type
- Rectangular Sample Cell
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 30 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| External Dimensions | 34 × 34 × 32 mm |
| Cell Body Dimensions | 34 × 34 × 32 mm |
| External Dimensions Scope | Body Only |
| Body Height | 32 mm |
| Internal Dimensions | 30 × 30 × 30 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Open Top |
| Opening Configuration | Open Top (Cell Body) |
| Wall Thickness | 2 mm |
Choose this option
Choose C304CR5 when you need a 30 mm path in an open rectangular cell rather than a covered or stoppered format. The 30 × 30 × 30 mm internal sample region gives broad access from above for pipetting, manual rinsing and visual checking before measurement, and the Four-Way Light layout lets you work through any of the four side faces used by your optical setup.
What makes this option different
- Open-top access gives direct entry to the sample chamber, which is useful for filling, emptying and rinsing from above without working through a narrow neck or fitted closure.
- 30 mm optical path suits methods built around this longer side-to-side path length, so you can select the cell around the path your procedure already specifies.
- Four-Way Light geometry provides optical access through all four side faces, which helps when your holder or viewing arrangement needs side access from more than one direction.
- 30 × 30 × 30 mm internal chamber gives a broad square sample region that is easy to inspect visually during filling and cleaning.
- 34 × 34 × 32 mm body-only size keeps the outside shape compact while still leaving a wide open chamber at the top for handling.
- Fused integrated construction is the supplier’s construction term for this cell. For an open-top assembled cell like this, the practical point is straightforward handling and cleaning of the chamber and optical faces as one body, rather than selecting it for a separate removable plate or closure system.
Using this cell
Fill the cell from the top opening and check that the liquid level covers the beam region used by your instrument. Before measurement, remove visible bubbles from the optical path and keep the outer optical faces clean and dry.
Because the chamber is open at the top, the sample remains directly exposed during handling. That is useful for direct access, but your procedure should account for splash risk, airborne contamination or evaporation if those matter for the sample being measured.
First-use check
- Inspect all four side faces for chips, dust or residue.
- Rinse the chamber with a suitable liquid for your method before first use.
- Place the empty cell in the holder and confirm stable seating and top clearance.
- After filling, run a blank and confirm that the beam region is fully covered.
Fit and optical alignment
The stated 34 × 34 × 32 mm dimensions apply to the cell body only. Use them to check holder seating, compartment clearance and top access around the opening, especially if you fill by pipette or rinse the chamber manually in place.
Z Height is not established for this SKU. If your instrument or holder depends on a defined beam-center height, check that separately instead of assuming it from the 32 mm body height.
Solvents and cleaning
This quartz cell is listed for UV/Vis use across 200–2500 nm. For background on cuvette construction approaches and general care, see the MQ cuvette fabrication glossary.
The exact chemical limits for this selected assembly are not established here, so check compatibility if your sample or cleaning routine involves aggressive chemicals, elevated temperature or long contact time. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning on the optical faces.
Included with this option
Supplied as 1 rectangular sample cell. An included closure is not established for this SKU.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions for changes to dimensions, optical path length, chamber geometry or fit requirements. Send a dimensioned drawing or labelled sketch with holder details, beam-height requirements, sample conditions and target quantity through our contact page, and quote C304CR5.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.