(C502CS6) Quartz High-Capacity Cuvette, 50 mm Path, 125 mL
Original price was: $179.00.$162.00Current price is: $162.00.
C502CS6 is a JGS1 quartz high-capacity cuvette with a 50 mm optical path, a 125 mL nominal capacity and an open-top chamber supplied with a lid. Its Two-Way Light layout is suited to UV/Vis transmission measurements that use a large square sample region rather than a small analytical cell. Sold as 1 cuvette.
Description
C502CS6 is a JGS1 quartz high-capacity cuvette for UV/Vis work with a 50 mm optical path and a 125 mL nominal capacity. Its large 50 × 50 × 53 mm internal chamber suits methods that need a long transmission path through a substantially larger filled sample region, while the open top and supplied lid let you fill the cell directly and then cover it for handling or measurement.
- Path Length
- 50 mm
- Sample Volume (Nominal)
- 125 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | High-Capacity Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 50 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 125 mL |
| External Dimensions | 54 × 54 × 55 mm |
| Cell Body Dimensions | 54 × 54 × 55 mm |
| External Dimensions Scope | Body Only |
| Internal Dimensions | 50 × 50 × 53 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C502CS6 when your method calls for a 50 mm transmission path and a large square chamber rather than a compact cuvette format. The open-top access is practical for direct filling, rinsing and inspection, and the supplied lid covers the opening after loading. This version is intended for Two-Way Light transmission measurements through two opposing optical faces.
What makes this option different
- 50 mm optical path for methods written around a longer transmission distance.
- 125 mL nominal capacity with a 50 × 50 × 53 mm internal chamber for larger sample fills.
- Open-top chamber with lid so you can pour or pipette directly into the cell, then cover the opening for handling or measurement.
- Two-Way Light layout for direct transmission through opposing optical faces rather than side-access optical geometries.
- Fused integrated construction as the supplier’s construction term, paired with the wide top opening for straightforward rinsing and routine cleaning of the sample chamber.
- 54 × 54 × 55 mm body size in a square format that should be checked against holder width, depth and top clearance requirements.
Using this cell
Fill the chamber from the top so the liquid covers the beam path used by your instrument. After filling, remove visible bubbles from the optical region and place the lid as needed for your handling or measurement setup.
The wide square opening is useful when the sample is added by direct pouring or larger-volume pipetting. Keep the same face orientation for blank and sample if your method depends on a fixed optical alignment.
First-use check
Inspect the optical faces, top opening and lid for dust, chips or handling marks before first use. Rinse the chamber with a liquid suitable for your method, then place the empty cell in the holder to confirm seating and clearance before loading a full sample.
Fit and optical alignment
The listed 54 × 54 × 55 mm dimensions describe the body only. They do not include the lid, so check the available height in your holder or instrument compartment if you plan to measure with the cell covered.
Z Height is not listed for this SKU. If your instrument uses a fixed beam position, confirm beam height against your holder or fixture instead of relying on the overall body size alone.
Solvents and cleaning
This cuvette uses JGS1 quartz with a supplier-described fused integrated construction. In ordinary use, that construction is paired with the open-top chamber for direct rinsing and cleaning of the sample space after filling and measurement.
A detailed chemical compatibility list is not established for this exact option, so aggressive chemicals, heated conditions and long contact times should be reviewed for the full wetted assembly before use. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Wipe the optical faces gently with non-abrasive optical tissue. For general background, see fabrication methods of cuvettes.
Included with this option
This listing is for one C502CS6 cuvette supplied with a lid.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need different dimensions, path length, chamber size or other fitting details, we can review a custom JGS1 quartz version. Send a drawing or labelled sketch, your holder or instrument details, and your sample conditions through the contact page, and reference C502CS6.
Additional information
| Weight | 100 g |
|---|