(C502CR4) Quartz Large-Window Cuvette, 10 mm Path, 17.5 mL
Original price was: $142.00.$128.00Current price is: $128.00.
C502CR4 is a JGS1 quartz large-window cuvette with a 10 mm optical path, Two-Way Light layout and 17.5 mL nominal capacity. The open-top body gives direct access for filling, inspection and cleaning in methods that use a larger sample chamber. Sold as 1 cuvette per price unit, with a closure included.
Description
C502CR4 is a JGS1 quartz large-window cuvette for transmission measurements with a 10 mm optical path and 17.5 mL nominal capacity. Its open-top format gives direct access to the sample chamber, which is useful when you need easier filling, rinsing or visual checking than a more compact cell format allows.
This option also uses a larger 52.5 × 12.5 × 45 mm body, so selection is not only about path length. It suits setups that can accommodate this larger cuvette format and methods where the nominal volume and top access are part of the handling requirement.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 17.5 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Large-Window Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 17.5 mL |
| External Dimensions | 52.5 × 12.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 52.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C502CR4 when you want a 10 mm quartz transmission cell but need the handling space of a large-window body. The combination of a standard 10 mm path, open-top access and 17.5 mL nominal capacity makes it easier to load, rinse and inspect samples in applications that are not limited to a compact cuvette slot.
What makes this option different
- 10 mm optical path for standard transmission measurements in a larger-body cuvette format.
- Two-Way Light layout for a defined straight-through optical path across the cell.
- 17.5 mL nominal capacity for methods that use a larger sample chamber.
- Open-top access for direct filling, rinsing and visual inspection from above.
- JGS1 quartz construction for use across the stated 200–2500 nm range.
- Closure included with the listed cuvette sale unit.
- Fused integrated construction stated by the supplier for this exact option.
Using this cell
Fill the cell from the top and seat it so the transmission faces are aligned with the instrument beam. Before measurement, make sure the liquid level covers the optical region used by your method and remove visible bubbles, streaks or fingerprints from the light path.
The stated 17.5 mL is the nominal capacity of the cell. It is not a minimum working volume, so low-fill methods should be checked in your own holder and beam geometry before routine use.
First-use check
Inspect the optical faces and edges on arrival for dust or handling marks, then rinse as appropriate for your method before first use. A dry fit in the holder and a blank measurement at the intended wavelength are practical first checks before introducing sample.
Fit and optical alignment
The body size is 52.5 × 12.5 × 45 mm, which is the key fit point to review before ordering. This matters if your holder, chamber cover or retaining hardware is designed around a shorter or narrower cuvette body.
Z Height is not specified for this listing. If your instrument has a fixed beam height, confirm that requirement against the actual beam position in your setup rather than relying only on the outside dimensions.
Solvents and cleaning
This cuvette is made from quartz. Do not use hydrofluoric acid on quartz, and avoid hot strong alkalis or abrasive cleaning methods that can damage optical surfaces.
The supplier describes this exact option as a fused integrated construction. For general background on MQ cuvette fabrication approaches, see fabrication options. If your sample or cleaning routine involves specific organic solvents, elevated temperature or long soaking steps, please review those conditions with us before ordering for this SKU.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz cuvettes for projects involving different dimensions, optical path length, sample volume, optical windows, Z Height, closures, connections and tolerance requirements. Send a dimensioned drawing or labelled sketch together with your holder details, wavelength range, sample chemistry and quantity. Discuss your requirements and mention part number C502CR4.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.