(C505CR4) Quartz Rectangular Sample Cell, 50 mm Path
Original price was: $285.00.$257.00Current price is: $257.00.
C505CR4 is a JGS1 quartz rectangular sample cell with a 50 mm optical path, Five-Way Light access and an open-top chamber for direct filling. Its 54 × 54 × 55 mm body and 50 × 50 × 53 mm internal chamber suit UV/Vis setups that need a long path in a deep square sample region. Supplied as 1 cell.
Description
C505CR4 is a JGS1 quartz rectangular sample cell for UV/Vis work with a 50 mm optical path, an open-top body and Five-Way Light geometry. The deep square chamber gives direct access from above for filling and rinsing. Align its optical faces with the beam arrangement used by your method. This option is supplied as 1 cell.
The body measures 54 × 54 × 55 mm, with an internal chamber of 50 × 50 × 53 mm. That combination makes this version useful when you want a long optical path in a deeper rectangular cell rather than a shallow body. Nominal capacity and Z Height are not established here, so selection should be based on chamber shape, holder support and beam position rather than a volume figure.
- Path Length
- 50 mm
- Cell Type
- Rectangular Sample Cell
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 50 mm |
| Light Transmission Configuration | Five-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| External Dimensions | 54 × 54 × 55 mm |
| Cell Body Dimensions | 54 × 54 × 55 mm |
| External Dimensions Scope | Body Only |
| Body Height | 55 mm |
| Internal Dimensions | 50 × 50 × 53 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Open Top |
| Opening Configuration | Open Top (Cell Body) |
| Wall Thickness | 2 mm |
Choose this option
Choose C505CR4 when you need a 50 mm path length together with a deep, open square chamber and optical access from more than the two usual side faces. The open top makes manual loading, rinsing and visual inspection straightforward, and the taller 55 mm body gives more internal depth for sample handling or custom bench layouts. It is a practical choice for fixtures that can use the cell body dimensions directly and where beam height can be checked in the actual setup.
What makes this option different
- 50 mm optical path for methods built around a longer transmission length.
- Five-Way Light geometry with multiple optical faces to align with your measurement geometry.
- Open-top chamber for direct filling, rinsing and top access during setup.
- Deep square sample region with 50 × 50 × 53 mm internal dimensions in a 55 mm high body.
Using this cell
Fill from the open top and make sure the liquid level covers the beam region used in your instrument or optical bench. Remove visible bubbles from the intended light path and keep the same orientation between blank and sample when your method depends on a fixed alignment.
The open-top format is convenient for direct access, but it should be treated as an open sample cell rather than a sealed assembly. If your method depends on a cover, controlled headspace or pressure handling, plan that separately before ordering.
First-use check
- Inspect the optical faces and base for chips, residue or transit damage.
- Rinse with a cleaning method suitable for quartz and your sample chemistry.
- Place the empty cell in the holder and confirm seating and required beam access.
- Run a blank before routine measurements.
Fit and optical alignment
The listed 54 × 54 × 55 mm dimensions apply to the cell body only. Check holder opening, seating depth, beam access and surrounding clearance.
Five-Way Light describes the supported optical access category for this cell, not automatic compatibility with a specific instrument. Z Height is not stated for this SKU, so fixed-beam instruments should be checked against the intended sample region before purchase.
Solvents and cleaning
Quartz is used here for UV/Vis spectroscopy over the stated 200–2500 nm range. For general fabrication background, see Compare fabrication options.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. The chemical limits for this exact assembly are not established here, so if your sample or cleaning routine involves aggressive chemicals, please review the full liquid conditions with us before ordering.
Included with this option
1 rectangular sample cell with open-top body. No additional closure or accessory is specified for this listing.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review related custom JGS1 quartz versions for changes to dimensions, optical path length, chamber geometry, openings or fabrication requirements. Send a dimensioned drawing or labelled sketch together with your holder or instrument details, sample conditions and target quantity. You can contact us here and quote part number C505CR4.