(C502CE5) Quartz Rectangular Sample Cell, 50 mm Path
Original price was: $190.00.$171.00Current price is: $171.00.
C502CE5 is a JGS1 quartz rectangular sample cell for UV/Vis spectroscopy with a 50 mm optical path and a Two-Way Light layout. Its open-top 50 × 50 × 53 mm sample region gives broad top access for filling and helps you plan beam coverage and liquid depth in a larger square body. Sold as 1 cuvette per sale.
Description
C502CE5 is a JGS1 quartz rectangular sample cell for UV/Vis spectroscopy with a 50 mm optical path and a Two-Way Light layout. Its open-top square chamber gives direct access for filling, rinsing and checking the sample surface from above, while the 50 × 50 × 53 mm internal region and 54 × 54 × 55 mm body size help you plan beam coverage, filling depth and holder space together. This option is sold as 1 cuvette per sale.
- Path Length
- 50 mm
- Cell Type
- Rectangular Sample Cell
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 50 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| External Dimensions | 54 × 54 × 55 mm |
| Cell Body Dimensions | 54 × 54 × 55 mm |
| External Dimensions Scope | Body Only |
| Body Height | 55 mm |
| Internal Dimensions | 50 × 50 × 53 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Open Top |
| Opening Configuration | Open Top (Cell Body) |
| Wall Thickness | 2 mm |
Choose this option
Choose C502CE5 when your method uses a 50 mm straight-through path and you want a broad rectangular sample chamber rather than a narrow cuvette body. The open top suits direct filling and visual checks before measurement, and the larger square format is useful when your fixture or compartment is built to support this kind of cell body.
What makes this option different
- 50 mm optical path gives a defined longer transmission distance for methods set up around this path length, so selection depends on your optical method as well as available holder space.
- Two-Way Light layout means the cell is arranged for transmission through two opposite optical faces, which suits straight-through UV/Vis measurement rather than multi-side optical access.
- Open-top access lets you fill, rinse and inspect the sample directly from above without working through a narrow neck or threaded closure.
- 50 × 50 × 53 mm internal sample region provides a broad filled area to plan liquid coverage across the beam path and to judge filling depth in the cell body.
- 54 × 54 × 55 mm body size makes this a larger square cell body that should be checked against holder support, compartment clearance and surrounding hardware.
- Fused integrated construction is the supplier’s construction term for this cell. In practical selection and handling, it indicates an integrated assembled quartz body rather than a body chosen by a separate MQ fabrication grade here, so cleaning and chemical choice should be based on the complete cell and your actual sample conditions.
Using this cell
Fill the chamber from the top and make sure the intended beam path passes through a fully covered part of the sample region during measurement. The open top makes it easier to spot bubbles, foam or particles at the surface before you place the cell in the holder.
Keep the same orientation for blank and sample runs. Handle the cell by the outer body where possible, and keep the optical faces clean and dry before measurement.
First-use check
Before first use, inspect the optical faces for residue or transport marks and rinse the chamber with a cleaning liquid suitable for your method. Then place the empty cell in your holder to check seating and run a blank after filling to confirm the beam passes through the intended sample region.
Fit and optical alignment
The stated 54 × 54 × 55 mm dimensions apply to the cell body only. Use them to check holder seating, side clearance and compartment space, especially if your setup is built around a larger square support rather than a standard slim-slot cuvette holder.
Z Height is not stated for this option. If your instrument or fixture depends on a defined beam-center height, confirm that point before ordering instead of using the overall body dimensions as an alignment value.
Solvents and cleaning
This quartz cell is listed for UV/Vis use over 200–2500 nm. For general construction background and selection guidance, see Compare fabrication options.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods. The exact chemical limits of this assembled option are not stated here, so if your samples or cleaning routine involve aggressive solvents, concentrated chemicals or long contact time, please check the full conditions before ordering.
Included with this option
Sold as 1 cuvette per sale. This option has an open-top body; confirm any required closure or accessories with your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch with your holder or instrument details, critical dimensions, sample chemistry and target quantity. Discuss your requirements and quote part number C502CE5.
Additional information
| Weight | 100 g |
|---|