(C052CR) Quartz Standard Cuvette, 5 mm Path, 1.75 mL
Original price was: $37.00.$34.00Current price is: $34.00.
C052CR is a JGS1 quartz standard cuvette with a 5 mm optical path, Two-Way Light layout and 1.75 mL nominal capacity. Its open-top body allows direct filling, a lid is included, and the listed uncapped body size is 12.5 × 7.5 × 45 mm.
Description
C052CR is a JGS1 quartz standard cuvette for methods that use a 5 mm optical path in a rectangular top-fill format. It combines Two-Way Light transmission with 1.75 mL nominal capacity, giving you a shorter-path cell that is easy to fill, inspect and rinse from above. A lid is included, and the stated 12.5 × 7.5 × 45 mm dimensions apply to the uncapped body for holder checks.
- Path Length
- 5 mm
- Sample Volume (Nominal)
- 1.75 mL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 5 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 12.5 × 7.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 7.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C052CR when your procedure is already written for a 5 mm cuvette and you want direct sample access from the top rather than a fixed closure or plate assembly. The open body suits routine pipette loading and cleaning, while the included lid provides a simple covered configuration for handling or use where that format is preferred. This option is also described for contact with acids, alkalis and organic liquids, making it the most relevant choice in this group when your method goes beyond neutral aqueous samples.
What makes this option different
- 5 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Two-Way Light: align the opposing optical faces with the transmission beam and use the same orientation for blank and sample readings.
- 1.75 mL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Accompanying closure: cover the opening after preparation and allow room to remove it; no pressure or leak-tight rating is specified.
Using this cell
Fill the cell from the top opening and make sure the liquid fully covers the beam during measurement. Remove bubbles before reading, and keep the same orientation for blank and sample when your method depends on repeatable positioning.
Handle the cuvette by the non-optical surfaces where possible. The included lid can cover the opening during use or between steps, but this remains an open-top cell body and no pressure limit or sealed-assembly rating is established here.
First-use check
Before first use, inspect the optical faces for residue or handling marks, rinse with a suitable liquid for your procedure, and run a blank to confirm clean beam passage through the intended window area. If you will use the lid during measurement, also check top clearance in your holder.
Fit and optical alignment
The listed 12.5 × 7.5 × 45 mm dimensions apply to the uncapped body. Use that body size to check holder seating and compartment fit, then allow for top clearance separately if you plan to use the lid in place.
Z Height is not stated for this option. If your instrument or holder depends on a defined beam-center height, confirm that requirement before ordering rather than assuming compatibility from the outside shape alone.
Solvents and cleaning
This quartz cuvette is described for contact with acids, alkalis and organic liquids, but the actual concentration, temperature, exposure time and contacting components are not defined here. Treat that as a general use direction rather than a universal compatibility list, especially where the lid or any wetted closure surface matters.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Wipe the exterior optical faces gently with non-abrasive optical tissue. For broader fabrication background, see Compare fabrication options.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections. Send a dimensioned drawing or labelled sketch, together with holder details, sample conditions and target quantity, through Discuss your requirements and quote part number C052CR.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.