Site Navigation

(MQQFL029) JGS1 Quartz Fluorescence Cuvette, 40/10 mm Paths, 15 mL

Weight50 g
SKU: MQQFL029

$461.00

In Stock

JGS1 quartz fluorescence cuvette with 40 mm and 10 mm optical paths, Five-Way Light access and a 15 mL nominal capacity. The open-top body is supplied with a flat lid for covered handling between filling and measurement. Price is for 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFL029 combines a broad 40 mm path with a 10 mm secondary path in one JGS1 quartz fluorescence cuvette. Its Five-Way Light layout and open-top body make it useful when your method needs more than one optical direction around the same sample chamber. The flat lid covers the opening during handling, and the nominal capacity is 15 mL.

Path Length
40 mm / 10 mm (dual path)
Sample Volume (Nominal)
15 mL
Opening Configuration
Open Top

Selection Specifications

Product KindCuvette
Cell TypeFluorescence Cuvette
Measurement ModeUV/Vis Spectroscopy; Fluorescence Spectroscopy
Path Length40 mm / 10 mm (dual path)
Light Transmission ConfigurationFive-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)15 mL
External Dimensions42.5 × 12.5 × 45 mm
Body Height45 mm
Base Dimensions42.5 × 12.5 mm
Internal Dimensions40 × 10 × 43 mm
MaterialQuartz
Material GradeJGS1
Closure TypeFlat Lid
Closure IncludedYes
Fabrication MethodMolded 0.01
Opening ConfigurationOpen Top
Pack Quantity1 Piece

Choose this option

Choose MQQFL029 when you need a larger rectangular sample chamber with two defined path directions and optical access from multiple faces. This format suits UV/Vis and fluorescence work where the cell geometry, not just the nominal path length, matters for holder fit, beam arrangement and how you load the sample from above.

What makes this option different

  • 40 mm and 10 mm paths: two optical directions in the same cell body for methods built around those path lengths.
  • Five-Way Light layout: multiple optical access faces for arranging excitation, transmission and collection geometry.
  • 40 × 10 × 43 mm internal chamber: a broad sample region paired with a 15 mL nominal capacity.
  • Open top with flat lid: direct filling and visual access from above, with the lid supplied for covered handling.

Structure and dimensions

MQQFL029 body dimensions and flat lid. The selected cell has 40 / 10 mm optical paths.
MQQFL029 body dimensions and flat lid. The selected cell has 40 / 10 mm optical paths.Open image ↗
Alternative sizes in the series. The listed MQQFL029 option supplies one cell with a flat lid.
Alternative sizes in the series. The listed MQQFL029 option supplies one cell with a flat lid.Open image ↗

Using this cell

Fill the cell from the open top and place the lid after loading if your handling routine calls for cover between steps. When changing between the 40 mm and 10 mm directions, blank and measure in the same orientation you will use for the method rather than switching faces mid-run.

For fluorescence work, arrange excitation and collection around the accessible optical faces required by your setup. For UV/Vis measurements, use the selected path direction consistently and calculate against that path only.

First-use check

  1. Choose the optical direction required by your method before preparing the blank.
  2. Check holder fit, beam position and lid clearance with a blank in place.
  3. Keep the same cell orientation for blank and sample measurements.

Fit and optical alignment

Check the full body size, not only the path length, against your holder or instrument space. This cell has a 42.5 × 12.5 mm base footprint and a 45 mm body height, so it should be matched to fixtures that can accept its broader rectangular form and allow clearance above the opening for lid access.

Z Height is not established for this option. If your instrument has a fixed beam position, verify beam coverage with your holder or compare against a cell you already use. The 15 mL figure is nominal capacity, not a minimum working fill.

View the English selection reference. Also available in the product gallery.

English selection reference
Selection reference ↗

Solvents and cleaning

Molded 0.01 is the option to consider when your method calls for closely specified optical-path precision. For the 40 mm path on this cell, agree the required tolerance and measurement conditions for the order.

If your sample or cleaning routine involves aggressive chemicals, include the liquid, concentration, temperature and contact time when checking suitability.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis, abrasive cleaners and unnecessary force on the cell body. Clean the optical faces gently with non-abrasive optical tissue and a suitable cleaning liquid for your method.

Included with this option

One MQQFL029 quartz Fluorescence Cuvette with its accompanying flat lid. The price is per cell. Group photographs show alternative sizes in the series; they are not a multi-cell sales pack.

Availability and ordering

You can order the listed specification directly, or contact us first to check current availability. A temporarily unavailable option may need additional preparation or production time. For a required arrival date, please check timing before checkout; preparation and shipping transit are separate.

Discuss a custom version

If you need a different chamber layout, path combination or fit around a specific holder, send the required optical directions, holder dimensions and sample conditions with your enquiry. If path length, documentation or other dimensional points are critical to your application, include those requirements in the quotation request.

Custom enquiries generally use JGS1 quartz, with prototype batches typically involving 2–4 cells. Feasibility, final specifications, quantity, price and production time are confirmed in the quotation. Modified designs are quoted separately from the listed product.

Discuss your application — please quote MQQFL029, quantity and delivery destination.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFL029) JGS1 Quartz Fluorescence Cuvette, 40/10 mm Paths, 15 mL”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar