(MQQFC092) Quartz Flow Cell, 50 mm Path, 40 µL, Two Side Arms
$359.00
JGS1 quartz flow cell combining a 50 mm optical path with 40 µL nominal capacity. The narrow cylindrical section and two side arms have 3 mm OD / 1 mm ID dimensions; the drawing distinguishes a 52 mm axial span from the 20 mm side arms. Standard 80 adhesive-bonded construction for room-temperature aqueous methods; one cell supplied.
Description
MQQFC092 is a JGS1 quartz flow cell for UV/Vis setups that combine a 50 mm optical path with a 40 µL nominal capacity. Its narrow cylindrical section and two projecting side arms make optical alignment and lateral tubing clearance the main installation checks. The specified 50 mm optical path, 52 mm drawn axial span and 1 mm internal bore describe different dimensions.
This option is best selected by its long path, low nominal volume and side-arm layout rather than by holder size alone. The tube dimensions and the shown axial lengths are the practical details to check before installation, especially if your fixture has tight clearance around the connection points.
- Path Length
- 50 mm
- Sample Volume (Nominal)
- 40 µL
- Opening Configuration
- Two Side Tubes
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 50 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 40 µL |
| Outer Diameter (OD) | 3 mm |
| Inner Diameter (ID) | 1 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 3 mm |
| Tube Inner Diameter (ID) | 1 mm |
| Fabrication Method | Standard 80 |
| Opening Configuration | Two Side Tubes |
| Port Layout | Side arm near axial end A, shown at the top; Side arm near axial end B, shown at the bottom |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose MQQFC092 when your method needs a 50 mm UV/Vis flow path but the connection layout should stay alongside the body rather than rise from the top. The cylindrical geometry and side-tube arrangement are the key points to match against your holder, tubing route and the available space around the measurement position.
What makes this option different
- 50 mm optical path for methods built around a longer transmission length.
- 40 µL nominal capacity keeps the internal volume small for this path-length format.
- Two side tube connections change how tubing approaches the cell and how much side clearance the assembly needs.
- 3 mm OD / 1 mm ID quartz tubes provide specific connection dimensions to check during layout planning.
Using this cell
Support the cell body during setup and make tubing connections without using the projecting side tubes as lifting or clamping points. Fill slowly so the optical region is fully covered and bubbles do not remain in the light path.
For routine measurement, blank the system under the same circuit conditions used for the sample. The 40 µL value is the nominal cell capacity, not a stated minimum working volume, and any pumps, valves or added fittings should be considered as part of the complete flow path.
First-use check
- Inspect the optical faces and tube ends for chips, residue or visible contamination.
- Install the cell with a suitable blank and verify that the beam passes cleanly through the intended optical direction.
- After filling, recheck the measurement region for bubbles and repeat the blank in the installed position.
Fit and optical alignment
View the English selection reference.
The drawing shows a 52 mm axial span and side arms marked 20 mm. Check those projections as real clearance requirements around the holder or fixture, particularly if tubing must bend soon after the connection point.
The 50 mm optical path and the 1 mm internal bore describe different parts of the geometry. No Z Height is established for this SKU, so if your instrument depends on a specific beam-center height, that point should be checked at the fixture stage rather than assumed from the cylindrical form.

Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. It is generally suited to room-temperature water-based samples and buffer solutions. Avoid organic samples and organic cleaning solvents on this bonded assembly.
If your method uses organic solvents, aggressive chemicals, heated conditions or long contact times, ask about a more suitable construction before ordering. Keep hydrofluoric acid away from quartz, avoid hot strong alkalis and abrasive cleaning, and clean the exterior optical faces gently.
Included with this option
1 quartz flow cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review related custom JGS1 quartz flow-cell requirements such as path length, connection layout, body envelope and fabrication choice. Send your enquiry with SKU MQQFC092, your holder or tubing layout, sample conditions and required quantity.