(MQQFC095) Quartz Flow Cell, 10 mm Path, 32 µL, 8.5 mm Z Height
$179.00
JGS1 quartz flow cell with a 10 mm optical path, 32 µL nominal capacity and 8.5 mm base-to-beam-centre height. The 2 mm optical opening is separate from the two top liquid connections. Standard 80 adhesive-bonded construction for routine room-temperature aqueous samples and buffers; one cell supplied.
Description
MQQFC095 is a JGS1 quartz flow cell for UV/Vis measurements that need a 10 mm path in a compact flow-through format. Its 32 µL nominal capacity, 8.5 mm Z Height and two top quartz connections help when you need to match the cell to an existing holder, beam position and tubing layout rather than choosing by path length alone.
This version uses adhesive-bonded quartz construction and is classified as Standard 80. It is supplied as 1 piece.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 32 µL
- Opening Configuration
- Two Top Fluid Connections
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Z Height | 8.5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 32 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 35 mm |
| External Dimensions Scope | Installed Assembly |
| Body Height | 35 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 3 mm |
| Tube Inner Diameter (ID) | 1 mm |
| Fabrication Method | Standard 80 |
| Opening Configuration | Two Top Fluid Connections |
| Fitting Material | Quartz |
| Port Layout | Top connection at the left in the referenced original; Top connection at the right in the referenced original |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose MQQFC095 when your setup needs a 10 mm flow cell with a compact nominal volume and a defined beam-center height from the base. The 12.5 × 12.5 mm footprint and top-entry connection layout are useful where the holder is built around an upright cell body and side clearance is limited.
What makes this option different
The 2 mm opening is the optical aperture at the measurement region. It is not the bore of a liquid connection; compare the beam footprint and optical centre with your holder separately from the tubing connection.
- 10 mm optical path in a compact flow-through cell format.
- 32 µL nominal capacity for a small sample region within this path length.
- 8.5 mm Z Height gives a stated bottom-to-beam-center reference for alignment checks.
- Two top quartz connections with 3 mm OD and 1 mm ID define the connection size and clearance above the cell.
Using this cell
Install the cell upright and support the body rather than the projecting top connections. Fill the circuit gradually so the sample reaches the optical region without trapping bubbles, then run your blank under the same installed conditions used for measurement.
The 32 µL figure is a nominal cell volume, not a minimum working volume. Your total filled system volume will be higher once tubing and other inline parts are connected.
First-use check
- Inspect the optical faces and connection ends before installing the cell.
- Place the cell in the holder and verify that the beam aligns with the stated 8.5 mm Z Height.
- Run a blank after filling, then recheck for bubbles or exterior droplets in the optical area.
Fit and optical alignment
View the English selection reference.
The cell body is 12.5 × 12.5 mm with a 35 mm body height and a 45 mm overall height including the fixed top tubes. Compare the 8.5 mm Z Height with your instrument beam position, and leave room above the cell for tubing bends and connection access.
Two opposing optical faces describes the optical direction through the opposed measurement faces. It does not by itself establish fit in a particular instrument, so holder seating and beam position should be checked against your setup.

Solvents and cleaning
This cell uses adhesive-bonded quartz construction and is classified as Standard 80. This type is generally used for room-temperature water-based samples and buffers.
Avoid organic sample solvents and organic cleaning agents with this construction. If your method involves organic solvents, aggressive liquids, elevated temperature or long contact times, a more suitable Sintered or Molded option may be needed. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaners, and clean the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
1 Quartz Flow Cell. The listed price is for one cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz flow cells for changes to path length, capacity, body size, windows, Z Height and connection details. Send a product enquiry with SKU MQQFC095 together with your drawing or holder details, sample conditions and target quantity.