(MQQFC091) Quartz Flow Cell, 10 mm Path, 48 µL, 15 mm Z Height
$179.00
JGS1 quartz flow cell with a 10 mm optical path, 48 µL nominal capacity and 15 mm base-to-beam-centre height. The 2.5 mm optical opening is separate from the two top liquid connections. Standard 80 adhesive-bonded construction for routine room-temperature aqueous samples and buffers; one cell supplied.
Description
MQQFC091 is a JGS1 quartz flow cell for UV/Vis measurements with a 10 mm optical path and 48 µL nominal capacity. Its two top fluid connections keep tubing above the cell body, while the stated 15 mm Z Height gives you a defined beam-center reference when holder fit and optical alignment both matter.
This layout is useful when you need a compact flow cell without side connections projecting into nearby hardware. The 12.5 × 12.5 mm base and 35 mm body height help with holder planning, and the shown 45 mm overall height includes the fixed top tubes, so overhead clearance should be checked as part of the assembly.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 48 µL
- Opening Configuration
- Two Top Fluid Connections
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Z Height | 15 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 48 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 35 mm |
| External Dimensions Scope | Installed Assembly |
| Body Height | 35 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Two Top Fluid Connections |
| Fitting Material | Quartz |
| Port Layout | Top connection at the left in the referenced original; Top connection at the right in the referenced original |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose MQQFC091 when your method needs a 10 mm transmission path in a small quartz flow-cell body and your setup depends on a known optical center height. The top-entry connection layout suits installations where tubing should rise from the cell rather than extend sideways, which can simplify routing inside compact covers or crowded optical spaces.
What makes this option different
The 2.5 mm opening is the optical aperture at the measurement region. It is not the bore of a liquid connection; compare the beam footprint and optical centre with your holder separately from the tubing connection.
- 10 mm optical path for standard two-way transmission measurements in a flow-cell format.
- 48 µL nominal capacity supports small-volume flow work without implying a stated minimum working fill.
- 15 mm Z Height gives a defined base-to-beam-center reference for holder and beam-position checks.
- Two top fluid connections keep both connection points above the body for upward tubing access.
- 12.5 × 12.5 mm base with 35 mm body height helps when body footprint and vertical fit both affect your fixture choice.
- Standard 80 adhesive-bonded quartz construction is a practical choice for room-temperature aqueous and buffer-based methods.
Using this cell
Install the cell so the beam passes through the intended two-way optical direction, then connect both fluid lines from the top with enough slack to avoid pulling on the quartz connections. During filling, watch the optical region and clear visible bubbles before blanking or measuring.
Handle the cell by supporting the body, not by lifting it from the connections. The 48 µL figure is the nominal cell capacity, not a minimum working volume, so your final fill condition should be established in the assembled system you plan to use.
First-use check
- Inspect the optical faces and connection areas before installation.
- Verify that the holder supports the 12.5 × 12.5 mm base and provides clearance for the top connections.
- Run a blank after filling, then remove any visible bubbles or exterior droplets and repeat if needed.
Fit and optical alignment
View the English selection reference.
The base is 12.5 × 12.5 mm and the body height is 35 mm. The shown overall height is 45 mm including the fixed top tubes, so check body fit and the space above the cell separately if your holder has a lid, clamp or restricted headroom.
The stated Z Height is 15 mm from the base to the optical center. Use that dimension for beam-position planning, while keeping final fit dependent on your actual holder, beam size and installed tubing path.

Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. For routine selection, that makes it best suited to room-temperature water-based samples and buffer solutions.
Avoid organic samples and organic cleaning solvents on this bonded assembly. Keep hydrofluoric acid away from quartz, avoid hot strong alkalis and abrasive cleaning methods, and wipe the outer optical faces gently.
Included with this option
1 quartz flow cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz flow cells for changes to path length, body envelope, Z Height, connection layout and fabrication choice. Send your enquiry with SKU MQQFC091, holder details, critical dimensions, sample conditions and quantity.
Design notes for this configuration: 48 µL Quartz Flow Cell: Matching a 15 mm Measurement Centre (MQQFC091)
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.