Site Navigation

(MQQFC037) Quartz Rectangular Sample Cell, 2 mm Path, 120 µL, Open at Both Ends

Weight50 g
SKU: MQQFC037

$227.00

In Stock

Quartz rectangular sample cell with a 2 mm optical path, Four-Way Light access and 120 µL nominal capacity. Its open-at-both-ends JGS1 quartz body suits custom mounting or sealing arrangements where a compact 4 × 3.2 × 30 mm envelope matters. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC037 is a JGS1 quartz rectangular sample cell for UV/Vis work from 200 to 2500 nm. It combines a 2 mm optical path with Four-Way Light access in a slim open-ended body, which is useful when you need a short transmission path but want to define the end support, sealing or sample-handling arrangement in your own fixture. The nominal capacity is 120 µL, with a 2 × 2 × 30 mm internal chamber inside a 4 × 3.2 × 30 mm exterior.

View the English selection reference. Group photographs in the gallery may show related options in the series.

Path Length
2 mm
Sample Volume (Nominal)
120 µL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length2 mm
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)120 µL
External Dimensions4 × 3.2 × 30 mm
Body Height30 mm
Base Dimensions4 × 3.2 mm
Internal Dimensions2 × 2 × 30 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodStandard 80
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose MQQFC037 when your setup needs a narrow rectangular cell body with a 2 mm path and light access from two face pairs. The open-at-both-ends format suits built-in assemblies, special holders and other layouts where you will manage filling, retention and end treatment outside the cell body itself.

What makes this option different

  • 2 mm optical path for methods built around a short transmission distance.
  • Four-Way Light configuration for optical access through two opposed face pairs.
  • Open at both ends so the cell can be integrated into a custom fixture instead of used as a finished capped cuvette.
  • Compact 4 × 3.2 × 30 mm exterior for tight holder layouts, with a 2 × 2 × 30 mm internal chamber.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

This is an open sample body rather than a ready-to-connect flow cell. Before use, decide how the sample will be introduced, retained and removed at the two open ends, especially if the cell will be part of a larger assembly.

Keep the measurement orientation consistent between blank and sample, and align the beam to the intended 2 mm path. The stated 120 µL is the nominal chamber volume, not a minimum working volume for a completed fixture or sealed assembly.

First-use check

  1. Inspect the optical faces and end edges for chips, residue or handling marks.
  2. Test the fit in the holder before introducing sample.
  3. Run a blank in the intended orientation and confirm that filling and bubble control work as planned.

Fit and optical alignment

Use the 4 × 3.2 × 30 mm outer dimensions to check holder clearance, and use the 2 × 2 × 30 mm dimensions only for the sample chamber. Because the body is open at both ends, any sealing parts, tubing or mounting features must come from your own assembly design.

Z Height is not specified for this SKU. If your instrument or holder uses a fixed beam position, check the actual beam alignment in the installed geometry rather than assuming it from body height alone. Support the body evenly and avoid concentrated clamping pressure on the optical faces or end edges.

English selection reference
Selection reference ↗

Solvents and cleaning

Standard 80 is the MQ fabrication designation for this adhesive-bonded quartz construction. It is best suited to routine room-temperature aqueous samples and buffers.

Avoid organic samples and organic cleaning solvents with this bonded assembly. If your method involves organic solvents or heated treatment, ask about a more suitable Sintered or Molded alternative before ordering. Keep hydrofluoric acid away from quartz, and avoid hot strong alkalis and abrasive cleaning methods.

Included with this option

1 rectangular sample cell, SKU MQQFC037. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We can review custom JGS1 quartz projects involving path length, body dimensions, nominal volume, optical access, Z Height, end interfaces and fabrication requirements. Please send your drawing or holder details, sample conditions, required quantity and delivery target through this contact page.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC037) Quartz Rectangular Sample Cell, 2 mm Path, 120 µL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare