(MQQSC073) Quartz Screw-Top Cuvette, 1/44 mm Dual Path, M6, PTFE Cap
$833.00
JGS1 quartz screw-top cuvette with 1 mm and 44 mm optical paths and six-sided optical access. The shallow 50 × 7 × 50 mm body has an M6 filling neck and a supplied PTFE screw cap; height is 62 mm uncapped and 65 mm with the cap fitted. Molded 83 fabrication; one cell with its cap supplied.
Description
MQQSC073 combines a short 1 mm optical path and a 44 mm secondary path in a shallow quartz body. Six-sided optical access supports different measurement orientations, while the single M6 threaded neck provides access for filling and accepts the supplied PTFE screw cap.
- Path Length
- 1 mm / 44 mm (dual path)
- Cell Type
- Screw-Top Cuvette
- Opening Configuration
- Single Threaded Neck
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 1 mm / 44 mm (dual path) |
| Light Transmission Configuration | Six-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Cell Body Dimensions | 50 × 7 × 50 mm |
| Overall Height without Closure | 62 mm |
| External Dimensions Scope | Body Only |
| Overall Height with Closure | 65 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Material | PTFE |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Single Threaded Neck |
| Closure Thread | M6 |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Screw-Top Cuvette; Accompanying PTFE screw cap |
Choose this option
Choose this cell when your method and holder are designed around the 1 mm / 44 mm path combination. The thin body and projecting neck need to be considered together: the optical body is 50 × 7 × 50 mm, the uncapped height including the neck is 62 mm and the height with the cap fitted is 65 mm.
What makes this option different
- Two optical paths in one body: select the intended 1 mm or 44 mm measurement direction through the cell orientation. Keep that orientation consistent between the blank and sample.
- Six-sided optical access: the accessible optical faces provide options for beam entry and observation. They do not represent six fluid ports or separate sample chambers.
- M6 screw-top filling neck: the removable PTFE cap covers the filling opening between handling steps. The thread identifies the closure fit; it does not establish a pressure rating or an oxygen-exclusion specification.
- Shallow optical body: the 7 mm body thickness is distinct from the full clearance needed around the neck and cap. Check your holder around the complete assembly.
Using this cell
Fill through the single neck until the measurement region is covered without bubbles, then remove exterior droplets from the optical faces. Establish a working fill for your actual beam height and orientation; a minimum working volume is not specified. Handle the cell by non-optical areas and fit the cap gently without loading the quartz neck.
First-use check
- Inspect the optical faces, threaded neck and cap for damage or residue.
- Check seating, neck clearance and the intended optical direction before filling.
- Run a suitable blank at the measurement wavelength, remove bubbles and keep the same orientation for the sample.
- After handling, recheck that the beam passes through the filled region and that exterior faces are clean.
Fit and optical alignment
Check the 50 × 7 × 50 mm optical body separately from the 62 mm uncapped and 65 mm capped heights. The body thickness does not define the cap diameter or complete assembly envelope. Verify beam access and beam-centre height in your own holder rather than using the overall height as Z Height.
View the English selection reference.

Solvents and cleaning
This JGS1 cell uses Molded 83 fabrication. Select sample and cleaning conditions for the complete assembly, including the quartz body and PTFE cap. For organic solvents, heated cleaning or prolonged exposure, confirm suitability for the actual chemical, concentration, temperature and contact time before use; the fabrication designation alone is not a limit for the assembled cell.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Wipe exterior optical faces gently with non-abrasive optical tissue and use a cleaning liquid compatible with every wetted component.
Included with this option
One quartz screw-top cuvette with its PTFE screw cap. The listed price is for one cell with the accompanying cap.
Availability and ordering
Contact us to confirm current availability and dispatch timing for your quantity. For a required delivery date, check timing before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects involving path length, body dimensions, optical windows, closure geometry and fabrication requirements. Modified designs and prototype batches are quoted separately from this SKU. Send your drawing or holder sketch, sample conditions and quantity through the contact page, and include MQQSC073.
Additional information
| Weight | 90 g |
|---|
You must be logged in to post a review.












Reviews
There are no reviews yet.