Site Navigation

(MQQFC007) Quartz Rectangular Sample Cell, 0.6 mm Path, 14 µL, Open at Both Ends

Weight50 g
SKU: MQQFC007

$419.00

In Stock

MQQFC007 is a JGS1 quartz rectangular sample cell with a 0.6 mm optical path, Four-Way Light access and 14 µL nominal capacity. Open at both ends, it is supplied as 1 piece for use in your own holder, sealing or fluid-handling arrangement. Standard 80.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC007 is a JGS1 quartz rectangular sample cell with a 0.6 mm optical path, 14 µL nominal capacity and Four-Way Light layout. Open at both ends, it is intended for users who need a very small rectangular sample channel inside their own fixture, seal or custom assembly rather than a finished cell with built-in fittings.

The combination of a 0.6 × 0.6 × 40 mm internal channel and a 12 × 12 × 40 mm outer body helps you plan both optical access and mechanical support. This option is sold as one open-ended cell body.

Path Length
0.6 mm
Sample Volume (Nominal)
14 µL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length0.6 mm
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)14 µL
External Dimensions12 × 12 × 40 mm
Body Height40 mm
Base Dimensions12 × 12 mm
Internal Dimensions0.6 × 0.6 × 40 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodStandard 80
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose MQQFC007 when you need a very short 0.6 mm path together with optical access from more than one side of the cell body. The open-at-both-ends format is useful when your fixture, seals or connected hardware define how the sample is introduced and retained, and when the 12 × 12 mm outer cross-section suits your holder design.

View the English selection reference.

What makes this option different

  • 0.6 mm optical path with a 0.6 × 0.6 × 40 mm internal channel for a very small rectangular sample region.
  • Four-Way Light layout for optical access from additional side faces as well as the main transmission path.
  • Open at both ends so sealing, filling and any fluid connections can be designed around your own assembly.
  • 12 × 12 × 40 mm exterior for checking holder space and body support separately from the channel size.
  • Standard 80 adhesive-bonded quartz construction for routine room-temperature aqueous samples and buffers.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Use this cell as an open-ended sample chamber within a separately prepared mounting arrangement. Align the beam to the intended path, keep the same orientation for blank and sample, and remove visible bubbles or exterior droplets before recording data.

Because both ends are open, sample retention depends on your own seals, interfaces or holder design. The 14 µL value is the nominal cell volume; once end interfaces or connected dead volume are added, the full assembled liquid volume can be different.

First-use check

  1. Inspect the optical faces, end edges and channel openings for dust or handling residue.
  2. Check body support and beam alignment in the intended fixture before introducing sample.
  3. Test your sealing and filling arrangement with a blank liquid before measurement.

Fit and optical alignment

Use the 12 × 12 × 40 mm exterior to check body support, holder opening and beam clearance. The 0.6 × 0.6 × 40 mm internal dimensions describe the sample chamber and should not be treated as holder-fit dimensions.

Z Height is not established for this listing, so it should not be treated as a direct match for instruments or fixtures that require a known beam-center height. Open ends also do not create a fluid connection, pressure rating or leak-tight assembly by themselves.

English selection reference
Selection reference ↗

Solvents and cleaning

Standard 80 is an adhesive-bonded quartz construction and is generally chosen for routine room-temperature aqueous samples and buffers. If your method involves organic samples, organic cleaning solvents or heated treatment, ask about a more suitable construction before ordering.

Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the exterior optical faces gently with non-abrasive optical tissue.

Included with this option

1 MQQFC007 rectangular sample cell. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; the final quantity, feasibility, specifications, price and production time are confirmed in the project quotation.

Send a product-selection enquiry with SKU MQQFC007, your drawing or holder details, sample conditions, quantity and delivery destination.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC007) Quartz Rectangular Sample Cell, 0.6 mm Path, 14 µL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar