Circular Quartz Gas Cell: Viewing a Sample Through Opposed Flat Faces
CUSTOM DESIGN GUIDE · MQAVC003
MQAVC003 combines a circular quartz body with opposed viewing faces and one stoppered neck. The reference has a 10 mm sample path and nominal 20 mL capacity. The form separates the circular optical region from the smaller access opening at its edge.

Use and purpose · Specifications · In practice · Custom example · Buy or enquire
The sample path crosses the circular body
The body is 55 mm outside and 51 mm inside diameter, with a 14 mm outside thickness. The 10 mm path is the distance through the sample between the viewing faces. Body diameter and sample distance describe different directions.
This is a useful reference for a proposed gas-observation arrangement using the flat faces. The circular outline can be supported around its perimeter, leaving the selected viewing region exposed. It is a closed viewing body with neck access, rather than an open dish with a removable top.
MQAVC003 configuration
One neck gives the cell an orientation
The neck is 7 mm outside and 5 mm inside diameter. The labelled envelope is 75 mm in the neck direction and 78 mm with the stopper fitted. A round mount still needs to leave space at that particular point around the perimeter.
A drawing of the mount can therefore identify the viewing centre and neck direction together. The stopper's removal route extends beyond its closed position, and it should remain accessible after the body is located in the holder.
Access and continuous flow are different requirements
The single opening provides one access point for the proposed filling and handling routine. It does not supply separate inlet and outlet routes. A method that needs continuous exchange through two connections would call for a different port layout.
The sample gas and operating state belong to the complete arrangement. The illustrated body and stopper do not establish an allowable evacuation or pressure. The useful starting information is the optical region, access routine and mount, followed by the operating specification for the intended system.
A custom example: move access away from the mount contact
ILLUSTRATIVE DESIGN EXAMPLE
Suppose the chosen perimeter support meets the existing neck position. A proposed version can retain the circular viewing body and 10 mm path while placing the access neck elsewhere. The drawing includes the open stopper route as well as the closed outline, so the change solves the handling problem too.
Order the listed configuration or discuss a change
View MQAVC003 and current pricing. For a custom version, send a labelled sketch that separates the features to retain from the changes you want.
For MQAVC003, mark the viewing region, perimeter support and required neck direction. Describe filling and stopper access, the gas and operating conditions, then add quantity, destination and requested date.





Recent Comments