(C332WS) Quartz Flow Cell, 33 mm Path, 2.3 mL
Original price was: $2,280.00.$2,052.00Current price is: $2,052.00.
Quartz flow cell for UV/Vis spectroscopy with a 33 mm optical path, 2.3 mL nominal capacity and Two-Way Light geometry. This version combines two top M6 threaded ports, 6.5 × 11 mm windows and a 15 mm Z Height in a 35.5 × 12.5 × 35 mm cell body. This page covers the shown C332WS specification.
Description
C332WS is a quartz flow cell for UV/Vis spectroscopy with a 33 mm optical path, a 2.3 mL nominal capacity and Two-Way Light geometry. It combines a longer flow-cell path with a larger chamber than micro-volume designs, while keeping a defined 15 mm Z Height and top M6 threaded connections for installation planning.
- Path Length
- 33 mm
- Sample Volume (Nominal)
- 2.3 mL
- Opening Configuration
- Two Top Fluid Connections
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 33 mm |
| Light Transmission Configuration | Two-Way Light |
| Z Height | 15 mm |
| Optical Window Dimensions | 6.5 × 11 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 2.3 mL |
| Cell Body Dimensions | 35.5 × 12.5 × 35 mm |
| Body Height | 35 mm |
| Base Dimensions | 35.5 × 12.5 mm |
| Material | Quartz |
| Port Count | 2 |
| Port Thread | M6 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Two Top Fluid Connections |
| Fitting Material | PTFE |
Choose this option
Choose this cell when you need a 33 mm path in a flow cell with a larger nominal chamber and threaded top connections rather than plain tube ends. The two top M6 ports can simplify fitting selection and upward tubing runs, while the 6.5 × 11 mm windows and 15 mm Z Height help you check beam access and holder alignment before installation.
What makes this option different
- 33 mm optical path for UV/Vis flow measurements that call for a longer absorbance path.
- 2.3 mL nominal capacity in a larger chamber than a micro-flow format.
- Two top M6 threaded ports for matching threaded fittings and planning tubing clearance above the cell.
- 6.5 × 11 mm windows with a 15 mm Z Height provide useful optical and alignment references.
Using this cell
Install suitable fittings for the M6 top ports, connect the liquid lines, and fill the chamber slowly so the optical region wets evenly. Before measurement, check that the flow path is fully filled and free of visible bubbles.
The nominal 2.3 mL capacity describes the cell chamber itself. It does not include the liquid volume in external fittings, tubing or any loop outside the cell, so total system volume should be considered separately during priming and sample changeover.
No pressure rating is stated for this SKU. If you plan to use it in a pressurized circuit, review the complete assembled fluid path before operation.
First-use check
- Inspect the window faces and threaded port areas before installation.
- Confirm that your M6 fittings suit the cell and do not interfere with holder clearance.
- Fill slowly, check the connected system, and make sure the optical path is free of bubbles before measuring.
Fit and optical alignment
The confirmed cell body dimensions are 35.5 × 12.5 × 35 mm. Use those body dimensions to check holder seating, and leave extra space above the cell for the top-mounted M6 connections and any fittings you attach.
Use the 15 mm Z Height and the 6.5 × 11 mm window size when comparing the cell to your instrument beam position and beam footprint. The full installed envelope with fittings is not established here, so clearance should be reviewed if the sample compartment is tight. Two-Way Light describes the opposing measurement faces only and does not by itself confirm compatibility with a particular spectrometer holder.
Solvents and cleaning
Molded 83 is an MQ fabrication option often chosen for methods involving organic solvents and temperature-controlled work. Select the sample and cleaning routine for the complete wetted assembly, including the PTFE threaded fittings, not only the quartz body.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. For aggressive reagents or extended exposure, check suitability for the complete assembled flow path before use.
Included with this option
The listed price is for one C332WS flow cell.
Additional accessory contents should be confirmed for your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and connection details that are critical to your setup. Discuss your requirements and quote part number C332WS.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.










Reviews
There are no reviews yet.