(C052WC) Quartz Flow Cell, 5 mm Path, 650 µL
Original price was: $475.00.$428.00Current price is: $428.00.
C052WC is a JGS1 quartz flow cell with a 5 mm optical path, 650 µL nominal capacity and two opposed tube openings. Its slim 12.5 × 7.5 mm base and 4 mm OD / 2 mm ID tube dimensions suit compact flow setups, and it is supplied as 1 flow cell.
Description
C052WC is a JGS1 quartz flow cell with a 5 mm optical path and 650 µL nominal volume in a slim rectangular format. With a 12.5 × 7.5 mm base, a 25 mm body height and opposed tube openings, it fits compact flow setups that need a narrower body than a 12.5 mm square cell while still using a true flow-through quartz sample region.
- Path Length
- 5 mm
- Sample Volume (Nominal)
- 650 µL
- Opening Configuration
- Two Opposed Tube Openings
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 650 µL |
| External Dimensions | 12.5 × 7.5 × 47 mm |
| Body Height | 25 mm |
| Base Dimensions | 12.5 × 7.5 mm |
| Internal Dimensions | 10 × 5 × 13 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 4 mm |
| Tube Inner Diameter (ID) | 2 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | Two Opposed Tube Openings |
Choose this option
Choose C052WC when you need a narrower-body flow cell with a 5 mm optical path and a defined 650 µL nominal capacity. The opposed tube layout and 4 mm outer tube diameter give useful connection information up front when you are planning how the cell will sit in the holder and how tubing will approach from each end.
What makes this option different
- 5 mm optical path for methods built around a shorter transmission length than a 10 mm flow cell.
- 650 µL nominal capacity gives a defined sub-millilitre cell volume for flow-through work.
- Slim 12.5 × 7.5 mm base narrows the body in one direction for tighter holder spaces.
- Opposed tube openings place the fluid connections at opposite ends of the cell.
- 4 mm OD / 2 mm ID tube dimensions help you check connection size and tubing transition before installation.
Using this cell
Connect the opposed tubes into your liquid circuit and fill the cell gradually so the optical region wets without trapping bubbles. Once filled, inspect the sample region, then establish the blank under the same flow conditions you plan to use for measurement.
The nominal 650 µL figure refers to the cell itself. Tubing, unions and any external fittings add separate volume to the overall system.
No pressure limit is stated for this option, so pressure suitability should be checked before using it in a pressurized circuit.
First-use check
- Inspect the optical faces and both tube ends for chips, contamination or transport damage.
- Confirm that the holder supports the 12.5 × 7.5 mm base and leaves room for the full 47 mm external length.
- Fill with blank solution first, then check for bubbles, leaks and baseline stability before running sample.
Fit and optical alignment
This model has confirmed external dimensions of 12.5 × 7.5 × 47 mm, where the 47 mm overall length includes the tube structure. The body height alone is 25 mm, so use the full external dimensions for installation clearance and the base dimensions for holder seating.
The internal dimensions are 10 × 5 × 13 mm, but the 13 mm internal height is not Z Height. Z Height is not specified for this cell, so beam-center alignment should be checked against your instrument or holder before ordering.
Solvents and cleaning
This cell uses Molded 83 fabrication, a quartz construction commonly chosen for organic-solvent methods and temperature-controlled work. Suitability still depends on the complete wetted assembly and on your actual chemical conditions.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the exterior optical faces gently with non-abrasive optical tissue and remove sample residue promptly from the flow path.
Included with this option
This listing is for one flow cell of the listed specification. Additional package details are not specified here.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz flow cells for changes to dimensions, optical path, capacity, windows or Z Height, tube or port style, and fabrication or tolerance requirements. Send a dimensioned drawing or labelled sketch, plus holder details, sample conditions and quantity.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.









Reviews
There are no reviews yet.