(C104CE8) Quartz Micro Cuvette, 10 mm / 2 mm (dual path) Path, 700 µL
Original price was: $452.00.$407.00Current price is: $407.00.
JGS1 quartz micro cuvette for fluorescence work with a 10 mm primary path, 2 mm secondary path and Four-Way Light access around the sample region. This option combines a 700 µL nominal capacity with a compact 12.5 × 12.5 × 45 mm uncapped body and a supplied lid. Sold as 1 cuvette per price unit.
Description
C104CE8 is a JGS1 quartz micro cuvette for fluorescence measurements that use a 10 mm / 2 mm dual-path layout. Its Four-Way Light configuration gives optical access from four sides around the sample region, while the 700 µL nominal capacity and compact 12.5 × 12.5 × 45 mm uncapped body help when you need a small-format cell rather than a full-volume square cuvette. A lid is included, and this MQ listing is sold as 1 cuvette per price unit.
- Path Length
- 10 mm / 2 mm (dual path)
- Sample Volume (Nominal)
- 700 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm / 2 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 2 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Detection Channel Width | 2 mm |
Choose this option
Choose this cell when your method is built around the stated 10 mm primary path and 2 mm secondary path, and you want four-side optical access in a compact fluorescence cuvette. The 700 µL nominal capacity suits small-volume handling, while the square body format helps with holder planning where space around the sample position matters.
What makes this option different
- 10 mm primary path with a 2 mm secondary path for methods that use this dual-path geometry.
- Four-Way Light layout for optical access from four vertical sides around the sample region.
- 700 µL nominal capacity in a compact micro-cuvette format.
- 12.5 × 12.5 × 45 mm uncapped body, with lid height to be considered separately in your setup.
Using this cell
Fill from the top so the illuminated sample region is fully covered during measurement, and remove visible bubbles before placing the cell in the holder. Keep the same orientation for blank and sample runs if your procedure depends on the stated path direction.
The 700 µL figure is the nominal capacity of the cell. It is not a stated minimum working volume, so lower fills should only be used when the liquid level still covers the beam position in your instrument.
First-use check
- Inspect the optical faces and top opening for dust, marks or residue.
- Rinse with a sample-compatible liquid before first measurement.
- Place the cell in the holder and confirm stable seating and top clearance.
- Run a blank and verify that the filled sample covers the beam area used by your method.
Fit and optical alignment
The body dimensions given here are for the uncapped cell: 12.5 × 12.5 × 45 mm. This helps with holder clearance and seating checks, especially in compact fluorescence assemblies, but you should allow extra vertical space for the included lid.
Z Height is not specified for this SKU. If your instrument has a fixed beam center or limited vertical adjustment, check beam position against the actual illuminated region rather than assuming compatibility from the Four-Way Light format alone.
Solvents and cleaning
This cuvette is described with Molded 83 fabrication. This style is commonly selected for organic-solvent methods and temperature-involved applications, but suitability still depends on the complete assembled cell and lid under your actual conditions.
Chemical limits for this exact SKU are not listed here. Check sample chemistry, concentration, temperature, contact time and cleaning liquid for the full assembly before routine use. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
Supplied as 1 cuvette with a lid included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch and include holder or instrument information, application wavelength and sample conditions. Discuss your requirements and quote part number C104CE8.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.