C505CR2 is a JGS1 quartz high-capacity cuvette with a 50 mm optical path, 125 mL nominal capacity and Five-Way Light geometry. Its open-top square chamber gives broad optical access for fluorescence setups, and this version is supplied without a lid. Sold as 1 cuvette.
Description
C505CR2 is a JGS1 quartz high-capacity cuvette for fluorescence work with a 50 mm optical path, a 125 mL nominal capacity and Five-Way Light geometry. The open-top body gives direct access to a large 50 × 50 × 53 mm sample chamber, and this version is supplied without a lid.
- Path Length
- 50 mm
- Sample Volume (Nominal)
- 125 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | High-Capacity Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 50 mm |
| Light Transmission Configuration | Five-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 125 mL |
| External Dimensions | 54 × 54 × 55 mm |
| Cell Body Dimensions | 54 × 54 × 55 mm |
| External Dimensions Scope | Body Only |
| Internal Dimensions | 50 × 50 × 53 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | No |
| Opening Configuration | Open Top |
Choose this option
Choose C505CR2 when your method needs a long 50 mm path together with broader optical access around a large-volume square chamber. The open-top, no-lid format suits workflows where you want direct access to the sample region for filling, rinsing or inspection, while the Five-Way Light configuration is intended for measurement layouts that use more than a simple two-face transmission path.
What makes this option different
- 50 mm optical path for methods written around a longer optical distance.
- Five-Way Light geometry for multi-direction optical access around the sample region.
- 125 mL nominal capacity with a 50 × 50 × 53 mm internal chamber.
- Open-top body supplied without a lid.
Using this cell
Fill the cell from the open top and make sure the liquid level covers the beam region used by your instrument. Keep the optical surfaces free from droplets, bubbles and dried residue, and use the same orientation for blank and sample if your method depends on a fixed optical layout.
The open-top format is straightforward for larger additions by pouring or pipetting and for direct rinsing between runs. Because this version has no supplied lid, plan your handling and measurement setup around an uncovered top.
First-use check
Before first use, inspect the optical faces for dust, fingerprints or chips, rinse with a cleaning liquid suitable for your method, and verify that the cell seats squarely in your holder. Run a blank at your working wavelengths and confirm that the filled sample covers the beam region used in your setup.
Fit and optical alignment
The listed 54 × 54 × 55 mm dimensions apply to the body only. Check your holder opening, seating area and surrounding clearance before ordering, especially if your setup uses clamps, enclosures or accessories around the top of the cell.
Five-Way Light identifies the optical access category, but it does not by itself define compatibility with a particular instrument or holder. Z Height is not listed for this model, so beam position should be checked against your own fixture rather than assumed from the overall body size.
Solvents and cleaning
Quartz is widely used for optical measurements, but a detailed chemical compatibility list is not provided for this exact option. If your method involves aggressive chemicals, long contact times or heated cleaning conditions, please check suitability before ordering.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods, and wipe the exterior optical faces gently with non-abrasive optical tissue. For general background on cuvette construction, see fabrication methods of cuvettes.
Included with this option
1 cuvette per listed price unit. Supplied without a closure.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch together with your holder or instrument information, sample conditions and target quantity through the contact page, and quote part number C505CR2.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.