Site Navigation

(C505CR7) Quartz Rectangular Sample Cell, 50 mm Path

Weight100 g
SKU: C505CR7

Original price was: $317.00.Current price is: $286.00.

In Stock

C505CR7 is a JGS1 quartz rectangular sample cell with a 50 mm optical path, Five-Way Light access and an included lid. Its 50 × 50 × 23 mm internal chamber gives you a broad covered sample region in a low 54 × 54 × 25 mm body. Supplied as 1 cell.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

C505CR7 is a JGS1 quartz rectangular sample cell for UV/Vis work with a 50 mm optical path, Five-Way Light access and an included lid. Its broad 50 × 50 × 23 mm internal chamber sits in a low 54 × 54 × 25 mm body, so it suits setups that need a wide covered sample region without a tall cell body. Supplied as 1 cell.

Path Length
50 mm
Cell Type
Rectangular Sample Cell
Closure Type
Flat Lid

Selection Specifications

Product KindCuvette
Cell TypeRectangular Sample Cell
Measurement ModeUV/Vis Spectroscopy
Pack Quantity1 Piece
Path Length50 mm
Light Transmission ConfigurationFive-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
External Dimensions54 × 54 × 25 mm
Cell Body Dimensions54 × 54 × 25 mm
External Dimensions ScopeBody Only
Body Height25 mm
Internal Dimensions50 × 50 × 23 mm
MaterialQuartz
Material GradeJGS1
Closure TypeFlat Lid
Closure IncludedYes
Wall Thickness2 mm

Choose this option

Choose C505CR7 when you need a 50 mm path in a rectangular quartz cell that combines broad sample access with a short body height. The covered format helps when you want the sample region protected during handling, while the wide chamber and multi-direction optical access give you more freedom in how the beam reaches the filled sample area. This option also uses fused integrated construction in the supplier’s terminology, which is a practical fit for users who want this square body and chamber arrangement as a fixed assembled cell rather than a demountable plate-style sample holder.

What makes this option different

  • 50 mm optical path for methods built around a longer transmission distance through the sample.
  • Five-Way Light configuration gives this cell optical access from multiple faces, which is useful when your holder or beam approach benefits from more than one available light direction.
  • Broad 50 × 50 × 23 mm internal chamber provides a wide sample region for filling and visual checking before measurement.
  • Low 25 mm body height helps where vertical space is tighter than the footprint area.
  • Included lid keeps this as a covered sample-cell format rather than an open-top chamber.
  • Fused integrated construction means this is supplied as a fixed cell body, suited to routine filling, emptying and cleaning of the assembled chamber rather than disassembly into separate optical plates.

Using this cell

Fill the chamber so the liquid covers the beam region used by your instrument, then place the lid for measurement. The wide square chamber makes it easier to load and inspect the sample surface, but it is still important to remove visible bubbles from the optical path and to keep a consistent orientation between blank and sample runs when your setup is alignment-sensitive.

This is a static sample cell, not a flow cell or pressure-rated assembly. The lid gives you a covered chamber for normal handling, but it should not be treated as evidence of a sealed, leak-tight or chemically rated closure.

First-use check

  1. Inspect the optical faces, top edge and base for chips, residue or transport marks.
  2. Check that the cell sits flat and stable in your holder.
  3. Run a blank at your working wavelength and confirm the beam passes through the intended filled region.
  4. Make sure your filling, draining and cleaning routine suits the wide covered chamber format.

Fit and optical alignment

The stated 54 × 54 × 25 mm dimensions apply to the cell body only. Use them to check holder seating, base support and side clearance, then allow extra space above the cell because the assembled height with the lid is not stated here.

Five-Way Light describes the supported optical-access category for this SKU. In practical use, that means you can plan around several optical faces when positioning the cell in a holder, but final suitability still depends on your instrument’s beam location and fixture geometry. Z Height is not stated here, so instruments with a fixed beam height should be checked before ordering.

Solvents and cleaning

Quartz is specified here for UV/Vis use over the stated 200–2500 nm range. For general fabrication background, see Compare fabrication options.

Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Chemical limits for this exact assembled cell are not established here, so if your sample or cleaning routine involves aggressive acids, bases or organic solvents, please review the full conditions with us before ordering.

Included with this option

Supplied as 1 cuvette per sale. A closure is included. Other package contents are not specified here.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom enquiries that generally use JGS1 quartz for changes involving dimensions, optical path length, optical windows or Z Height, closures, fabrication and tolerance requirements. Send a labelled sketch or drawing together with holder or instrument details, critical dimensions, sample conditions and target quantity. Discuss your requirements and quote part number C505CR7.

Additional information

Weight100 g

Reviews

There are no reviews yet.

Be the first to review “(C505CR7) Quartz Rectangular Sample Cell, 50 mm Path”

You may also like…

10%
(C1002CS3) Quartz Colorimetric Cuvette, 100 mm Path, 60 mL

(C1002CS3) Quartz Colorimetric Cuvette, 100 mm Path, 60 mL

100 g
In Stock
Original price was: $223.00.Current price is: $201.00.
Add to Wishlist
Add to Wishlist
10%
(C602CR) Quartz Rectangular Sample Cell, 60 mm Path

(C602CR) Quartz Rectangular Sample Cell, 60 mm Path

100 g
In Stock
Original price was: $237.00.Current price is: $214.00.
Add to Wishlist
Add to Wishlist
10%
(C50.82CS) Quartz Colorimetric Cuvette, 50.8 mm Path, 30 mL

(C50.82CS) Quartz Colorimetric Cuvette, 50.8 mm Path, 30 mL

100 g
In Stock
Original price was: $84.00.Current price is: $76.00.
Add to Wishlist
Add to Wishlist
10%
(C50.82CS1) Quartz Colorimetric Cuvette, 50.8 mm Path, 30 mL

(C50.82CS1) Quartz Colorimetric Cuvette, 50.8 mm Path, 30 mL

100 g
In Stock
Original price was: $95.00.Current price is: $86.00.
Add to Wishlist
Add to Wishlist
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare