(C102SD1) Quartz Ultra-Micro Cuvette, 10 mm Path, 100 µL
Original price was: $142.00.$128.00Current price is: $128.00.
C102SD1 is a JGS1 quartz ultra-micro cuvette for UV/Vis spectroscopy with a 10 mm optical path, 100 µL nominal capacity and Two-Way Light layout. This version uses a stopper-equipped opening for covered sample handling and is identified for volatile solutions. Sold as 1 cuvette per listed price unit, with stopper included.
Description
C102SD1 is a JGS1 quartz ultra-micro cuvette for UV/Vis work when you want a 10 mm optical path without moving to a larger sample chamber. Its 100 µL nominal capacity supports small-volume preparation, while the stopper-equipped opening gives you a covered sample chamber during handling. This option is identified for volatile solutions and uses a Two-Way Light optical layout.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 100 µL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 100 µL |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
Choose this option
Choose C102SD1 when your method is built around a 10 mm UV/Vis path and you want a small nominal fill with a stopper rather than an open-top format. The covered opening can be useful when loading and moving volatile samples, and the 100 µL nominal capacity helps you plan preparation volume without treating the cell like a standard larger cuvette. This is a good fit for setups that use transmission through two optical faces and have clearance for this ultra-micro body style.
What makes this option different
- 10 mm optical path suits UV/Vis methods specified around this path length.
- 100 µL nominal capacity supports small-volume sample loading in an ultra-micro format.
- Stopper-equipped opening gives you covered access after filling, which is useful for handling volatile solutions.
- Two-Way Light configuration is arranged for measurement through two optical faces rather than side-access layouts.
- JGS1 quartz body makes it a quartz-cell option for UV/Vis laboratory use.
Using this cell
Load the sample carefully so the measurement region is fully covered, then seat the stopper gently. Check for bubbles before placing the cell in the holder, especially with small fills where a trapped bubble can sit in the optical path.
The nominal 100 µL figure describes the cell’s stated capacity, not a guaranteed minimum working volume. In use, the filled sample still needs to cover the beam path at the actual beam height of your instrument.
First-use check
- Inspect the optical faces and the stopper seating area before first use.
- Rinse with a liquid suitable for your method.
- Fill with a blank and confirm that the illuminated region is fully covered and free of bubbles.
- Insert sample and blank in a consistent orientation for repeat measurements.
Fit and optical alignment
This ultra-micro cell should be selected by actual holder clearance and beam position, not by family name alone. Two-Way Light means the measurement beam passes through two opposing optical faces, so the holder must position the cell correctly for that transmission path.
Z Height is not established here for customer specification use, and the external geometry is not fully released as a confirmed fit envelope. If your instrument has a fixed beam position or a close-tolerance holder, send the holder drawing, instrument model or key clearance details through Discuss your requirements.
Solvents and cleaning
This cell is made from quartz, but the chemical limits of the complete assembly for this exact option are not established here. If your method uses aggressive solvents, elevated temperatures, long contact times or unusual cleaning liquids, check those conditions before ordering.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. For general background on cuvette fabrication approaches, see Compare fabrication methods.
Included with this option
1 cuvette per listed price unit. Stopper included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication-related needs. Send a dimensioned drawing or labelled sketch, your instrument or holder details, sample conditions and target quantity through Discuss your requirements. Modified designs and prototype batches are quoted separately from the listed SKU.