(C302CE6) Glass Standard Cuvette, 30 mm Path, 10.5 mL
Description
C302CE6 is a glass standard cuvette built around a 30 mm optical path in a familiar rectangular format. Its 10.5 mL nominal capacity and top lid make it suitable for routine top filling where you want the sample opening covered during handling. The stated working range for this SKU is 350–2000 nm.
- Path Length
- 30 mm
- Sample Volume (Nominal)
- 10.5 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | Absorbance Spectroscopy |
| Path Length | 30 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 10.5 mL |
| External Dimensions | 32.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 32.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Glass |
| Closure Type | Lid |
| Closure Included | Yes |
Choose this option
Choose C302CE6 when your method specifically uses a 30 mm path and you want a standard cuvette body with a covered top opening rather than an uncovered open cell. The lid helps keep the opening covered between filling and measurement, while the larger nominal capacity suits methods that are set up for this longer path and fuller sample chamber.
What makes this option different
- 30 mm optical path for methods that are specified around that beam length.
- 10.5 mL nominal chamber: fill and inspect the long liquid region from above, keeping the measuring beam covered at your working fill level.
- Lidded top opening for direct filling from above with the opening covered during normal bench handling.
- Glass body with a stated 350–2000 nm range for visible to near-infrared use within that range.
- Supplier-described fused integrated construction as a fixed assembled cell body, not a plate-style cell opened for internal assembly.
- Uncapped body size of 32.5 × 12.5 × 45 mm for holder and clearance planning.
Using this cell
Fill the cell from the top opening and place the lid after filling if your handling routine benefits from covering the sample. Keep the optical faces clean and dry on the outside before measurement, and avoid touching those faces directly during loading.
The 10.5 mL figure is a nominal capacity, not a minimum working volume. If your method uses lower fill levels, check that the liquid level properly covers the beam in your own instrument setup.
First-use check
- Inspect each cuvette and the supplied closure for chips, cracks or visible residue.
- Check holder fit with the bare cell body, then confirm top clearance with the lid in place.
- Run a blank in the same orientation and lid arrangement you expect to use for the sample.
Fit and optical alignment
The verified dimensions apply to the uncapped cell body: 32.5 × 12.5 × 45 mm. Use those dimensions to check holder seating, then allow extra top clearance for the lid during loading and measurement.
Z Height is not established for this SKU. If your instrument or holder depends on a fixed beam-center height, do not rely on outer body dimensions alone to judge alignment.
Solvents and cleaning
This cuvette is described by the supplier as a fused integrated glass construction, so routine cleaning is done through the top opening on a fixed assembled body. In practice, that means rinsing promptly after use and cleaning the internal sample region from above rather than separating the cell into internal parts.
Exact chemical limits for this SKU and its full cell-and-lid assembly are not established here. If your work involves strong reagents or solvent cleaning, check the actual liquid, concentration, temperature and contact time before regular use. Avoid abrasive cleaning on the optical faces. For general background on cuvette construction options, see Compare fabrication methods.
Included with this option
The listed price covers 4 C302CE6 glass cuvettes with accompanying lids and a storage box.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need different dimensions, a different path length, another closure arrangement or a modified sample-cell design, send your drawing or labelled sketch together with holder details and sample conditions. You can contact us here: Discuss your requirements.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.