(C052CS4) Glass Standard Cuvette, 5 mm Path, 1.75 mL
Description
C052CS4 is a glass standard cuvette for visible absorbance spectroscopy with a 5 mm optical path and open-top filling. Its compact rectangular body, 1.75 mL nominal capacity and straightforward Two-Way Light transmission suit routine visible-light measurements where you want direct access from above rather than a closed or flow-through format. This selected option is sold as 1 cuvette and does not include a lid or box.
- Path Length
- 5 mm
- Sample Volume (Nominal)
- 1.75 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | Visible Absorbance Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 5 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 7.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 7.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Glass |
| Closure Type | Lid |
| Closure Included | No |
| Opening Configuration | Open Top |
Choose this option
Choose C052CS4 when your method uses visible-light absorbance with a 5 mm path in an open glass cell and your sample conditions stay within the supplier’s stated neutral-sample restriction. The open top makes manual filling and emptying simple, while the fused integrated construction wording points to a fixed cuvette body rather than a demountable sample chamber. That is useful for ordinary bench handling and cleaning where a familiar one-piece-style rectangular cell is preferred.
What makes this option different
- Restricted to neutral samples according to the supplier, which makes this option most suitable for routine neutral-sample work rather than broader chemical methods.
- Open-top access allows direct filling, emptying and rinsing from above without caps, fittings or removable plates.
- 5 mm optical path suits visible absorbance methods built around this shorter beam path.
- Two-Way Light layout supports ordinary straight-through transmission measurement through opposing faces.
- Fused integrated construction indicates a fixed cell body rather than a user-assembled chamber, which simplifies everyday handling and cleaning.
- No lid and no box included means this sales option should be planned as a bare open cell rather than a covered or stored set.
Using this cell
Fill the cell from the top and make sure the liquid covers the beam during measurement. Keep the same orientation for blank and sample when your method depends on consistent positioning, and handle the cuvette by the non-optical faces where possible to reduce fingerprints on the light path.
Because this is an open-top cell with no lid, it is best suited to routine manual filling where direct access matters more than closure. The 1.75 mL figure is a nominal capacity, not a minimum working volume, so your actual fill still depends on the beam position in your instrument.
First-use check
- Inspect the optical faces and top opening for chips, residue or handling marks.
- Place the empty cell in the holder and confirm stable seating and beam clearance.
- Run a blank in the same orientation you will use for the sample.
Fit and optical alignment
The listed external dimensions apply to the uncapped cell body: 7.5 × 12.5 × 45 mm. Check holder clearance against the bare cell and allow working space above the opening for filling and rinsing.
Z Height is not established for this option. If beam position is critical in your holder or spectrometer, check alignment against your actual setup before ordering instead of assuming it from the outside dimensions alone.
Solvents and cleaning
This option is restricted to neutral samples. A complete solvent-compatibility list is not established for this assembly, so if your method goes beyond neutral use or includes stronger cleaning chemicals, check suitability before use.
Clean gently with non-abrasive materials and avoid harsh cleaning practices that can mark the optical faces. For general background on cuvette construction and selection, see Fabrication Method of Cuvettes.
Included with this option
1 glass standard cuvette, open top. No lid is included with this sales option.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need the same general cell style with a different path length, material or related geometry, you can contact us about a custom version. Custom designs are quoted separately from this listed specification.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.