(MQQFC079) Quartz Flow Cell, 10 mm Path, 27 mL, Three Threaded Connections
$401.00
JGS1 quartz flow cell with a 10 mm optical path, 27 mL nominal capacity and three threaded fluid connections around a broad chamber. The quartz body is 60 × 51.5 × 14 mm with a stated 2 mm wall thickness; leave separate clearance for connection parts and tubing. Two opposing optical faces support transmission measurement; one cell supplied.
Description
MQQFC079 is a JGS1 quartz flow cell for UV/Vis measurements with a 10 mm optical path and 27 mL nominal capacity. Its broad body with three threaded flow connections is useful when the flow layout matters as much as the optical path, and the 60 × 51.5 × 14 mm body gives you a defined envelope for holder and tubing planning.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 27 mL
- Opening Configuration
- Three Threaded Flow Connections
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 27 mL |
| External Dimensions | 60 × 51.5 × 14 mm |
| Cell Body Dimensions | 60 × 51.5 × 14 mm |
| External Dimensions Scope | Body Only |
| Body Height | 14 mm |
| Base Dimensions | 60 × 51.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 3 |
| Opening Configuration | Three Threaded Flow Connections |
| Detachable Fittings | Yes |
| Wall Thickness | 2 mm |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose MQQFC079 when you need a two-way optical flow cell with a 10 mm path and a larger nominal chamber than a micro-volume format. The three threaded flow connections suit installations that need a fixed connection style around the cell body, while the flat rectangular footprint helps you review mounting space and line approach before ordering.
What makes this option different
- 10 mm optical path for standard two-way UV/Vis transmission measurements.
- 27 mL nominal capacity for methods that use a larger filled chamber; nominal capacity is not a minimum working volume.
- Three threaded flow connections on the cell body for planning several connection points around a single chamber.
- 60 × 51.5 × 14 mm body for checking holder clearance and tubing space around the installed cell.
Using this cell
Support the cell body securely and connect your tubing so the lines do not pull or twist the quartz during use. Bring flow in gradually and clear bubbles from the optical region before blank and sample readings, especially when the chamber is being filled for the first time.
The three connections serve the stated cell configuration; they do not establish three independent liquid circuits or fixed inlet and outlet roles. Plan port use and any unused-port treatment for your own liquid circuit. Match the complete connection and sealing geometry rather than inferring a nominal thread size or ring material from the photograph.
First-use check
- Inspect the optical faces and body for chips, residue or transit damage.
- Confirm that the cell sits securely in the holder and that tubing can be attached without side-loading the quartz body.
- After filling and bubble removal, run a blank and check that the signal is stable under your actual setup conditions.
Fit and optical alignment
View the English selection reference.
The body dimensions are 60 × 51.5 × 14 mm, with a stated 2 mm wall thickness. Check holder opening, side clearance and tubing access separately from those body dimensions, because the final installed space depends on the connection parts and line routing used in your setup.
Z Height is not specified for this SKU. If your instrument or holder uses a fixed beam height, verify beam position against your fixture before ordering.

Solvents and cleaning
Select sample and cleaning conditions for the complete wetted assembly, including the quartz body, connection parts, seals and any tubing you add. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning on optical faces.
Choose a cleaning method that matches your sample and rinse thoroughly so residue does not remain in the flow path. If your process involves aggressive chemicals, elevated temperature or long contact time, review the full wetted assembly for your actual conditions before use.
Included with this option
1 Quartz Flow Cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, body envelope or connection arrangement, send your drawing or labelled sketch with the critical dimensions and operating conditions. Custom enquiries are reviewed case by case, with specifications, quantity, price and production time confirmed for the project.
Send a product-selection enquiry with SKU MQQFC079 and your holder, tubing or application details.
Additional information
| Weight | 135 g |
|---|
You must be logged in to post a review.









Reviews
There are no reviews yet.