(MQQMC017) Quartz Ultra-Micro Cuvette, 10 mm path, 300 µL nominal capacity, Black Walls, 15 mm Z Height
$156.00
MQQMC017 is a JGS1 quartz ultra-micro cuvette with a 10 mm optical path, 300 µL nominal capacity and a 15 mm Z Height. Its open-top format, Two-Way Light layout and 3 × 10 mm optical window make it suitable for UV/Vis work where beam position and direct pipette access both matter. Supplied as 1 piece.
Description
MQQMC017 is a JGS1 quartz Ultra-Micro Cuvette for UV/Vis measurements with a 10 mm optical path and 300 µL nominal capacity. It combines an open top for direct filling with a 15 mm Z Height and a 3 × 10 mm optical window, which helps when your method needs a defined beam position in a compact sample region.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 300 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Z Height | 15 mm |
| Optical Window Dimensions | 3 × 10 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 300 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Ultra-Micro Cuvette |
Choose this option
Choose MQQMC017 when you want a 10 mm path in an ultra-micro format and your holder is arranged for a beam centre 15 mm above the cell bottom. The open-top body is convenient for manual loading, inspection and sample removal, and the 300 µL nominal capacity suits small-volume UV/Vis methods without moving to a flow cell or demountable assembly.
What makes this option different
- Open-top access allows direct pipetting into the sample chamber and easy visual checking before measurement.
- 10 mm optical path keeps the familiar transmission path length in a compact ultra-micro body.
- 15 mm Z Height is important when your holder or instrument uses a fixed beam position.
- Two-Way Light geometry supports transmission measurements through two opposing optical faces.
- 3 × 10 mm optical window defines the illuminated region and should be checked against your beam footprint.
- Standard 80 adhesive-bonded quartz construction is generally suited to room-temperature water-based samples and buffers.
Structure and dimensions

Using this cell
Fill the cell from the open top and make sure the liquid fully covers the light path during measurement. The 300 µL figure is a nominal capacity, not a minimum working volume, so the actual fill level still needs to suit your beam height, beam size and handling method.
Use the same orientation for blank and sample, especially in a small cell where beam placement matters. Check the sample region for bubbles before reading, and keep the optical faces free of droplets, fingerprints and residue.
First-use check
- Inspect the optical faces and top opening for chips, residue or contamination.
- Place the cell in the holder and verify that the beam aligns with the intended window area.
- Run a blank in the same orientation you will use for the sample and check for bubbles or exterior droplets.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The body dimensions are 12.5 × 12.5 × 45 mm for the bare cell body. Check holder seating, side clearance and vertical clearance against that body size before ordering.
The beam centre is specified at 15 mm above the bottom reference, and the optical window is 3 × 10 mm. If your instrument has a fixed beam position or a tight aperture, compare those points carefully with your holder and optical setup.

Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. It is generally suited to room-temperature water-based samples and buffers. Avoid organic samples and organic cleaning solvents with this adhesive-bonded cell.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning materials. Clean the optical faces gently with non-abrasive optical tissue and a suitable cleaning liquid for the complete assembly.
Included with this option
1 Quartz Ultra-Micro Cuvette.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or holder information, plus your sample conditions and target quantity.
Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation. Send a product-selection enquiry with SKU MQQMC017 and your application details.