(MQQMC023) Quartz Ultra-Micro Cuvette, 10 mm path, 100 µL nominal capacity, Black Walls, 20 mm Z Height
Description
MQQMC023 is a JGS1 quartz ultra-micro cuvette for UV/Vis spectroscopy with a 10 mm optical path, Two-Way Light geometry and 100 µL nominal capacity. Its 20 mm Z Height and 2 × 5 mm window area make it useful when beam position and optical footprint matter as much as path length.
The open-top body gives direct access for pipetting and visual inspection before measurement. In a compact cell like this, that helps when you need to check fill level, beam coverage and bubble-free loading in a small measurement region.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 100 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Z Height | 20 mm |
| Optical Window Dimensions | 2 × 5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 100 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Ultra-Micro Cuvette |
Choose this option
Choose MQQMC023 when your method needs a 10 mm UV/Vis path in an ultra-micro format and you must match both beam-center height and window size. The 20 mm Z Height is a practical selection point for holder alignment, while the 100 µL nominal capacity keeps the cell compact without changing to a special assembly style.
What makes this option different
- 20 mm Z Height for setups that require a defined beam-center position from the cell bottom.
- 2 × 5 mm window area for methods where beam footprint and optical clearance are limited.
- Two-Way Light configuration for transmission through two opposite optical faces.
- 100 µL nominal capacity in a compact open-top ultra-micro body.
- 10 mm optical path for standard path-length methods in a smaller sample chamber.
- Standard 80 adhesive-bonded construction for routine room-temperature water-based work rather than solvent-heavy use.
Structure and dimensions

Using this cell
Fill the cell from the open top and keep the same orientation for blank and sample measurements. Make sure the sample level fully covers the active beam area. The 100 µL value is a nominal capacity, not a stated minimum working volume.
Check carefully for bubbles in the window region before measurement, especially because the beam area is compact. Keep the optical faces free from fingerprints, droplets and dried residue so the transmission path stays clear.
First-use check
- Inspect the optical faces, top opening and body edges before first use.
- Verify holder fit and beam alignment with a suitable blank at the intended measurement position.
- Confirm that your fill level covers the beam path without bubbles in the window area.
Fit and optical alignment
View the English selection reference.
The body dimensions are 12.5 × 12.5 × 45 mm, body only, and the Z Height is 20 mm from the cell bottom to the beam center. Check holder clearance, insertion depth and beam position together. The 2 × 5 mm window area should also be matched to your beam footprint.
Two-Way Light describes the supported optical access category. It does not by itself establish compatibility with every holder or instrument, so review your beam geometry if your setup has tight optical tolerances.

Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. For this construction, room-temperature water-based samples and buffer solutions are the safest routine direction.
Avoid organic samples and organic cleaning solvents with this adhesive-bonded cell. If your work involves organic solvents, aggressive liquids, heat or long soaking times, please check the complete sample and cleaning conditions before use.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaners. Clean the exterior optical faces gently with non-abrasive optical tissue or similar laboratory wipes.
Included with this option
1 Quartz Ultra-Micro Cuvette.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes involving path length, body dimensions, window geometry, Z Height, sample volume, opening details and tolerances. Send your drawing or labelled sketch together with holder dimensions, beam-center information, sample conditions, quantity and target date.
Send a product-selection enquiry and include SKU MQQMC023 for reference.