(MQQSC049) Quartz Flow Cell, 10 mm Path, 3.5 mL, Central Screw Top and Two Side Connections
Description
MQQSC049 is a JGS1 quartz flow cell for UV/Vis spectroscopy with a 10 mm optical path, 3.5 mL nominal capacity and two opposing optical faces. This version combines a central M12 screw-top opening with two side flow connections, so you can access the sample region from above while still arranging a flow path through the same cell body. It is supplied with an accompanying PTFE closure.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Opening Configuration
- One Screw-Top Opening and Two Flow Connections
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 12.5 × 12.5 × 36 mm |
| Body Height | 36 mm |
| Overall Height with Closure | 66 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Material | PTFE |
| Closure Included | Yes |
| Port Count | 2 |
| Fabrication Method | Molded 83 |
| Opening Configuration | One Screw-Top Opening and Two Flow Connections |
| Port Layout | Left angled threaded flow connection as drawn; Right angled threaded flow connection as drawn |
| Closure Thread | M12 |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell; Accompanying closure |
Choose this option
Choose MQQSC049 when you want a 10 mm flow cell that offers both direct top access and side fluid connections in one assembly. The central screw opening is useful for filling, inspection or cleaning access, while the two side connections let you build a circulating or flushing setup around a compact square optical body.
What makes this option different
- 10 mm optical path with 3.5 mL nominal capacity for UV/Vis methods that use a larger flow-cell chamber.
- One central M12 screw opening plus two side flow connections for combined top access and connected fluid handling.
- PTFE closure included so this option is supplied with the central screw cap rather than as an open-top body.
- Molded 83 JGS1 quartz construction for applications requiring this fabrication option.
Using this cell
Plan how you will use the top opening before installation, whether for filling, inspection or cleaning access. Connect the side fluid lines with the body fully supported, then fill or flush the cell slowly so bubbles do not remain in the optical region before you establish the blank.
The stated 3.5 mL value is the nominal capacity, not a minimum working volume. In continuous-flow use, the total liquid held in the system will also include the connected tubing and any other inline parts.
No pressure rating is stated for this item. If your setup is pressurized, review the complete connection arrangement and operating conditions before use.
First-use check
- Inspect the optical faces, threads and connection areas before assembly.
- Test fit the cell with the closure and planned tubing route in place.
- After filling or flushing, run a blank and confirm that the optical area remains free of bubbles and exterior residue.
Fit and optical alignment
View the English selection reference.
The square optical body is 12.5 × 12.5 mm with a 36 mm body height. The bare cell reaches 62 mm including its necks; height with the cap is 66 mm. Check top clearance with the closure in place, allowing room to remove it without loading the side connections.
The side flow connections project beyond the 12.5 mm body width, so the installed envelope is wider than the square optical body itself. Z Height is not stated for this model, so instruments that depend on a defined beam-center height should be checked against the holder geometry before ordering.

Solvents and cleaning
Molded 83 is commonly chosen for methods involving organic solvents or elevated-temperature work, but suitability still depends on the complete assembly and actual conditions. If your process involves aggressive chemicals, prolonged contact or heat, review the liquid, concentration, temperature and contact time before routine use.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaners. Clean the optical faces gently, and rinse the flow path promptly after use so residues do not dry inside the cell.
Included with this option
1 MQQSC049 flow cell with PTFE screw cap. The listed price is for one cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, connection layout, body envelope or closure arrangement, send a drawing or labelled sketch with the critical dimensions and your sample conditions through the contact page, and mention SKU MQQSC049.
Additional information
| Weight | 50 g |
|---|